PartsTable TECHNICAL DATA SHEET
NSN 5950-01-069-6072Government record, cited

Transformer, Power5950-01-069-6072

NSN 5950-01-069-6072 · NIIN 010696072
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-069-6072 · 5950010696072 · NIIN 010696072 · 01-069-6072 · FSC 5950 Coils and Transformers · 68037540 · 97010100 · 97010100 · S-3754
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Transformer Winding Connection Type: DELTA-WYE
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Winding Power Rating: 45.1 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
  • Input-Output Phase Relationship: THREE PHASE TO SIX PHASE SINGLE COMPONENT
  • Mounting Method: SLOT SINGLE GROUP
Identification
  • NSN: 5950-01-069-6072
  • NIIN: 010696072
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-069-6072, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-069-6072
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Transformer Winding Connection TypeDELTA-WYE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Power Rating45.1 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
Input-Output Phase RelationshipTHREE PHASE TO SIX PHASE SINGLE COMPONENT
Mounting MethodSLOT SINGLE GROUP
Body Width3.020 INCHES MAXIMUM IN
Body Height3.688 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Maximum Operating Temp60.0 CELSIUS DEGC
Body Length4.781 INCHES MAXIMUM IN
Winding Operating Current8.2 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating380.0 HERTZ MINIMUM AND 500.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage5.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Winding Operating Voltage208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity8 PIN AND 3 WIRE HOOK
Mounting Slot Width0.156 INCHES NOMINAL SINGLE GROUP IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
68037540 5/2 Secondary reference
U.S. Government activity
97010100 3/9 Design control — primary reference
Syntegra / Usa/ Inc Computer Parts and Supplies ARH205
97010100 5/9 Secondary reference
Control Data Systems Inc Contracts Dept
S-3754 5/9 Secondary reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5950-01-069-6072?

NSN 5950-01-069-6072 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-069-6072?

Key specifications for 5950-01-069-6072: Transformer Winding Connection Type: DELTA-WYE; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-069-6072 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com