PartsTable TECHNICAL DATA SHEET
NSN 5950-01-068-5170Government record, cited

Transformer, Power5950-01-068-5170

NSN 5950-01-068-5170 · NIIN 010685170 · Part number 10966-1
Alliant Techsystems Operations Llc Div Defense Electronic Systems · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 06424
Government record, cited
NSN 5950-01-068-5170 — this item is cataloged by the U.S. Government under National Stock Number 5950-01-068-5170. Manufacturer of record part number: 10966-1.
Also searched as  5950-01-068-5170 · 5950010685170 · NIIN 010685170 · 01-068-5170 · FSC 5950 Coils and Transformers · CAGE 06424 · 10966-1 · IT-1143 · HYC01143 · HYC1143
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: UNTHREADED HOLE(S) SINGLE GROUP
  • Body Width: 3.812 INCHES NOMINAL IN
  • Body Height: 1.750 INCHES NOMINAL IN
Identification
  • NSN: 5950-01-068-5170
  • NIIN: 010685170
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 10966-1
  • Manufacturer: Alliant Techsystems Operations Llc Div Defense Electronic Systems
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-068-5170, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Alliant Techsystems Operations Llc Div Defense Electronic Systems. Government technical data includes 25 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-068-5170
Primary Part Number10966-1
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerAlliant Techsystems Operations Llc Div Defense Electronic Systems
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodUNTHREADED HOLE(S) SINGLE GROUP
Body Width3.812 INCHES NOMINAL IN
Body Height1.750 INCHES NOMINAL IN
Mounting Hole Diameter0.166 INCHES NOMINAL SINGLE GROUP IN
Winding Function and Quantity1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Maximum Operating Temp90.0 CELSIUS DEGC
Body Length3.812 INCHES NOMINAL IN
Winding Operating Current1.5 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current2.0 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current3.8 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current750.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating2.2 KILOHERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage15.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Voltage120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage18.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage38.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage66.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Terminal Type and Quantity16 TURRET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 2
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
2925-01-130-9265109661 POSSIBLE MATCH
RECTIFIER AND RESISTOR
Possible match (shared part number)Unison Industries Llc
4330-01-633-0795109661 POSSIBLE MATCH
FILTER BODY,FLUID
Possible match (shared part number)Clarus Technologies, Llc
Cross-Reference Index
Part NumberManufacturer
IT-1143 Hytronics Corp. (USA)
10966-1 PRIMARY Alliant Techsystems Operations Llc Div Defense Electronic Systems (USA)
Reference documents
ReferenceMeaning
HYC01143 5/9 Secondary reference
Hytronics Corp.
HYC1143 5/9 Secondary reference
Hytronics Corp.
Related Parts
2925-01-130-9265POSSIBLE MATCH
RECTIFIER AND RESISTOR
109661
4330-01-633-0795POSSIBLE MATCH
FILTER BODY,FLUID
109661

Frequently Asked Questions

What is NSN 5950-01-068-5170?

NSN 5950-01-068-5170 is a Transformer,power, manufactured by Alliant Techsystems Operations Llc Div Defense Electronic Systems, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-01-068-5170?

NSN 5950-01-068-5170 has 2 manufacturer part numbers on file: IT-1143 (Hytronics Corp.), 10966-1 (Alliant Techsystems Operations Llc Div Defense Electronic Systems).

What NSN replaces 5950-01-068-5170?

2 possible matches (shared part number, not a government interchangeability claim): 2925-01-130-9265, 4330-01-633-0795. Verify interchangeability with system specifications before substitution.

What are the specifications of 10966-1?

Key specifications for 10966-1: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 25 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-068-5170 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com