The Transformer,pulse, cataloged under National Stock Number 5950-01-058-2284, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-058-2284 |
| Item Name | Transformer,pulse |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 4.000 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS IN |
| Mounting Method | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| Inductance Rating | 0.286 HENRY NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Body Width | 4.060 INCHES NOMINAL IN |
| Body Height | 4.190 INCHES NOMINAL IN |
| Mounting Hole Diameter | 0.281 INCHES NOMINAL SINGLE GROUP IN |
| Winding Function and Quantity | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| Body Length | 5.190 INCHES NOMINAL IN |
| Winding Operating Current | 0.32 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| Winding Operating Current | 1.9 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| DC Resistance Rating in Ohms | 6.500 SINGLE COMPONENT SINGLE PRIMARY |
| DC Resistance Rating in Ohms | 70.000 SINGLE COMPONENT SINGLE SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 3.000 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS IN |
| Primary to Secondary Turn Ratio | 1 TO 2 SINGLE COMPONENT |
| Terminal Type and Quantity | 5 TAB, SOLDER LUG |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 146C653A01 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5950-01-058-2284 is a Transformer,pulse, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-058-2284: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 4.000 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS IN; Mounting Method: FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP. 19 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.