PartsTable TECHNICAL DATA SHEET
NSN 5950-01-052-1855Government record, cited

Transformer, Power5950-01-052-1855

NSN 5950-01-052-1855 · NIIN 010521855
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-052-1855 · 5950010521855 · NIIN 010521855 · 01-052-1855 · FSC 5950 Coils and Transformers · TT10606 · 154237 · TW-71359
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Winding Power Rating: 11.0 WATTS SINGLE COMPONENT SECOND SECONDARY
  • Winding Power Rating: 172.5 WATTS SINGLE COMPONENT SINGLE PRIMARY
  • Winding Power Rating: 28.0 WATTS SINGLE COMPONENT FIRST SECONDARY
  • Winding Power Rating: 380.0 MILLIWATTS SINGLE COMPONENT THIRD SECONDARY
Identification
  • NSN: 5950-01-052-1855
  • NIIN: 010521855
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-052-1855, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-052-1855
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Power Rating11.0 WATTS SINGLE COMPONENT SECOND SECONDARY
Winding Power Rating172.5 WATTS SINGLE COMPONENT SINGLE PRIMARY
Winding Power Rating28.0 WATTS SINGLE COMPONENT FIRST SECONDARY
Winding Power Rating380.0 MILLIWATTS SINGLE COMPONENT THIRD SECONDARY
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width3.062 INCHES MAXIMUM IN
Body Height4.875 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
Nominal Thread Size0.164 INCHES SINGLE GROUP IN
Body Length3.562 INCHES MAXIMUM IN
Winding Operating Current1.5 AMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Current2.0 AMPERES AC MINIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current2.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current500.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT SECOND SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Thread Quantity Per Inch32 SINGLE GROUP
Winding Operating Voltage22.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage14.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage190.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Terminal Type and Quantity8 SOLDER STUD
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 2
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
3940-01-185-4506TT1-606-5 POSSIBLE MATCH
SLING,TRIANGLE
Possible match (shared part number)Wear-Flex Slings Div M H S Ltd
2510-01-572-37511624432 POSSIBLE MATCH
FRAME SECTION,STRUCTURAL,VEHICUL
Possible match (shared part number)Crysteel Manufacturing, Inc Dba Crysteel Manufacturing Inc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
TT10606 3/9 Design control — primary reference
Magnetika/east Ltd Titan Transformer Div
154237 7/2 Vendor item drawing reference
Northrop Grumman Systems Corporation
TW-71359 C/1 Advisory reference — outside the item-of-supply concept
Magnetika
Related Parts
3940-01-185-4506POSSIBLE MATCH
SLING,TRIANGLE
TT1-606-5
2510-01-572-3751POSSIBLE MATCH
FRAME SECTION,STRUCTURAL,VEHICUL
1624432

Frequently Asked Questions

What is NSN 5950-01-052-1855?

NSN 5950-01-052-1855 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-01-052-1855?

2 possible matches (shared part number, not a government interchangeability claim): 3940-01-185-4506, 2510-01-572-3751. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-01-052-1855?

Key specifications for 5950-01-052-1855: Overall Height: 5.255 INCHES MAXIMUM IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-052-1855 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com