The Reactor, cataloged under National Stock Number 5950-01-050-4396, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 10 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-050-4396 |
| Item Name | Reactor |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Inclosure Type | FULLY INCLOSED |
| Mounting Method | TERMINAL SINGLE GROUP |
| Inductance Rating | 1.00 MILLIHENRIES MINIMUM AND 13.00 MILLIHENRIES MAXIMUM SINGLE COMPONENT SINGLE WINDING |
| Winding Operating Current | 30.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
| Rating Method | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
| Reliability Indicator | NOT ESTABLISHED |
| Winding Quantity | 1 SINGLE COMPONENT |
| Frequency Rating | 120.0 HERTZ NOMINAL SINGLE COMPONENT |
| Terminal Type and Quantity | 2 TAB, SOLDER LUG |
| Inductance Type | SWINGING |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| M1242 | 3/9 Design control — primary reference Myers Power Products, Inc. Dba Myers/abacus Div Myers Emergency Power Systems |
NSN 5950-01-050-4396 is a Reactor, classified under FSC 5950, Coils and Transformers. Status: active.
1 possible match (shared part number, not a government interchangeability claim): 4710-01-233-9770. Verify interchangeability with system specifications before substitution.
Key specifications for 5950-01-050-4396: Inclosure Type: FULLY INCLOSED; Mounting Method: TERMINAL SINGLE GROUP; Inductance Rating: 1.00 MILLIHENRIES MINIMUM AND 13.00 MILLIHENRIES MAXIMUM SINGLE COMPONENT SINGLE WINDING; Winding Operating Current: 30.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING. 10 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.