The Transformer,power, cataloged under National Stock Number 5950-01-041-5435, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-041-5435 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 2 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| Body Width | 2.380 INCHES NOMINAL IN |
| Body Height | 1.380 INCHES NOMINAL IN |
| Mounting Hole Diameter | 0.188 INCHES NOMINAL SINGLE GROUP IN |
| Winding Function and Quantity | 1 PRIMARY AND 7 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | EXTERNAL INCLOSURE SINGLE COMPONENT |
| Distance Between Mounting Facility Centers | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Maximum Operating Temp | 130.0 CELSIUS DEGC |
| Body Length | 2.750 INCHES NOMINAL IN |
| Winding Operating Current | 50.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
| Winding Operating Voltage | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 16.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Voltage | 21.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Voltage | 12.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Voltage | 12.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| Terminal Type and Quantity | 22 WIRE LEAD |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| HY-292-6064-2 | 7/9 Vendor item drawing reference Hyperion Industries Inc |
| HY-292-6064-2 | C/1 Advisory reference — outside the item-of-supply concept Dsk Engineering and Technology Inc |
| TT10880 | 3/9 Design control — primary reference Magnetika/east Ltd Titan Transformer Div |
NSN 5950-01-041-5435 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-041-5435: Mounting Facility Quantity: 2 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT; Mounting Method: FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP. 21 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.