PartsTable TECHNICAL DATA SHEET
NSN 5950-01-032-9369Government record, cited

Transformer, Power5950-01-032-9369

NSN 5950-01-032-9369 · NIIN 010329369
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-032-9369 · 5950010329369 · NIIN 010329369 · 01-032-9369 · FSC 5950 Coils and Transformers · 03000369 · 2994346 · 03000369
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: THREE PHASE TO THREE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED HOLE(S) SINGLE GROUP
  • Body Width: 3.140 INCHES MAXIMUM IN
  • Body Height: 4.630 INCHES MAXIMUM IN
Identification
  • NSN: 5950-01-032-9369
  • NIIN: 010329369
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-032-9369, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 17 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-032-9369
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipTHREE PHASE TO THREE PHASE SINGLE COMPONENT
Mounting MethodTHREADED HOLE(S) SINGLE GROUP
Body Width3.140 INCHES MAXIMUM IN
Body Height4.630 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
Nominal Thread Size0.164 INCHES SINGLE GROUP IN
Body Length4.630 INCHES MAXIMUM IN
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Thread Quantity Per Inch32 SINGLE GROUP
Terminal Type and Quantity3 TAB, SOLDER LUG AND 23 THREADED HOLE
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL B — Remove Demilitarization Key Points
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
03000369 3/2 Design control — primary reference
U.S. Government activity
2994346 7/2 Vendor item drawing reference
Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier
03000369 5/9 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-032-9369?

NSN 5950-01-032-9369 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-032-9369?

Key specifications for 5950-01-032-9369: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: THREE PHASE TO THREE PHASE SINGLE COMPONENT. 17 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-032-9369 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

What is the DEMIL code for NSN 5950-01-032-9369?

NSN 5950-01-032-9369 has DEMIL Code B. Demilitarization may be required before disposal or transfer to non-military entities.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com