PartsTable TECHNICAL DATA SHEET
NSN 5950-01-027-0694Government record, cited

Transformer, Power5950-01-027-0694

NSN 5950-01-027-0694 · NIIN 010270694
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-027-0694 · 5950010270694 · NIIN 010270694 · 01-027-0694 · FSC 5950 Coils and Transformers · LS-144 · LS-144 · 62656-1
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Transformer Winding Connection Type: DELTA-DELTA
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.765 INCHES MINIMUM AND 1.797 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: THREE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED HOLE(S) SINGLE GROUP
  • Body Width: 2.031 INCHES MAXIMUM IN
Identification
  • NSN: 5950-01-027-0694
  • NIIN: 010270694
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-027-0694, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-027-0694
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Transformer Winding Connection TypeDELTA-DELTA
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length1.765 INCHES MINIMUM AND 1.797 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED HOLE(S) SINGLE GROUP
Body Width2.031 INCHES MAXIMUM IN
Body Height1.531 INCHES NOMINAL IN
Winding Function and Quantity1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
Nominal Thread Size0.138 INCHES SINGLE GROUP IN
Maximum Operating Temp125.0 CELSIUS DEGC
Body Length2.281 INCHES MAXIMUM IN
Winding Operating Current375.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT ALL SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.015 INCHES MINIMUM AND 1.047 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
Winding Operating Voltage120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity9 TAB, SOLDER LUG
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL Q — CCL Item — Commerce Control List
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5340-01-280-5651LS1-4-4 POSSIBLE MATCH
CLAMP,BLOCK
Possible match (shared part number)Lockheed Martin Corp
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
LS-144 5/9 Secondary reference
U.S. Government activity
LS-144 5/1 Secondary reference
Magnetika Inc
62656-1 3/2 Design control — primary reference
U.S. Government activity
Related Parts
5340-01-280-5651POSSIBLE MATCH
CLAMP,BLOCK
LS1-4-4

Frequently Asked Questions

What is NSN 5950-01-027-0694?

NSN 5950-01-027-0694 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-01-027-0694?

1 possible match (shared part number, not a government interchangeability claim): 5340-01-280-5651. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-01-027-0694?

Key specifications for 5950-01-027-0694: Transformer Winding Connection Type: DELTA-DELTA; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.765 INCHES MINIMUM AND 1.797 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-027-0694 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

What is the DEMIL code for NSN 5950-01-027-0694?

NSN 5950-01-027-0694 has DEMIL Code Q. Demilitarization may be required before disposal or transfer to non-military entities.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com