The Transformer,power, cataloged under National Stock Number 5950-01-007-1792, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 16 specifications, cited from the U.S. Government catalog. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-007-1792 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| Body Width | 3.250 INCHES MAXIMUM IN |
| Body Height | 3.375 INCHES MAXIMUM IN |
| Criticality Code Justification | FEAT |
| Mounting Hole Diameter | 0.188 INCHES NOMINAL SINGLE GROUP IN |
| Winding Function and Quantity | 2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| Body Length | 3.938 INCHES MAXIMUM IN |
| Reliability Indicator | NOT ESTABLISHED |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 12.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
| Winding Operating Voltage | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| Terminal Type and Quantity | 8 WIRE LEAD |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | Y |
| Reference | Meaning |
|---|---|
| 9T56Y2357 | C/1 Advisory reference — outside the item-of-supply concept General Electric Co Fort Wayne Apparatus Service Shop |
| 9T58B2875 | 5/9 Secondary reference General Electric Co Large Transformer Business Div |
| 9T56Y1875 | 5/9 Secondary reference General Electric Co Large Transformer Business Div |
| 9T56Y2875 | 5/9 Secondary reference General Electric Co Large Transformer Business Div |
| 9T58K2875 | 3/9 Design control — primary reference General Electric Co Specialty Transformer Dept |
| 9T56Y2875 | C/1 Advisory reference — outside the item-of-supply concept General Electric Co Outdoor Breaker Business Section |
NSN 5950-01-007-1792 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-007-1792: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 16 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.