PartsTable TECHNICAL DATA SHEET
NSN 5950-00-994-6594Government record, cited

Transformer, Audio Frequency5950-00-994-6594

NSN 5950-00-994-6594 · NIIN 009946594
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-994-6594 · 5950009946594 · NIIN 009946594 · 00-994-6594 · FSC 5950 Coils and Transformers · TF4RX16AJ002 · MS90001A · MILT27
Nearby stock numbers  ·
Features
  • Transformer,audio Frequency — FSC 5950
  • Transformer Function: LINE
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 1.625 INCHES NOMINAL IN
  • Body Height: 2.375 INCHES NOMINAL IN
Identification
  • NSN: 5950-00-994-6594
  • NIIN: 009946594
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,audio Frequency, cataloged under National Stock Number 5950-00-994-6594, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 22 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-994-6594
Item NameTransformer,audio Frequency
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Transformer FunctionLINE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length1.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width1.625 INCHES NOMINAL IN
Body Height2.375 INCHES NOMINAL IN
Maximum Transformer Power Rating2.0 WATTS SINGLE COMPONENT
Winding Function and Quantity2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Impedance Rating in Ohms4.0 NOMINAL AND 16.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Impedance Rating in Ohms150.0 NOMINAL SINGLE COMPONENT ALL PRIMARY
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
Nominal Thread Size0.138 INCHES SINGLE GROUP IN
Maximum Operating Temp105.0 CELSIUS DEGC
Body Length1.625 INCHES NOMINAL IN
Reliability IndicatorNOT ESTABLISHED
Frequency Rating300.0 HERTZ MINIMUM AND 10.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Test Data Document81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Thread Quantity Per Inch32 SINGLE GROUP
Terminal Type and Quantity8 SOLDER STUD
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5950-01-058-4740 POSSIBLE MATCH
TRANSFORMER,AUDIO FREQUENCY
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
TF4RX16AJ002 5/2 Secondary reference
U.S. Government activity
MS90001A 2/2 Government specification standardization
U.S. Government activity
MILT27 4/1 Identification reference
U.S. Government activity
Related Parts
5950-01-058-4740POSSIBLE MATCH
TRANSFORMER,AUDIO FREQUENCY

Frequently Asked Questions

What is NSN 5950-00-994-6594?

NSN 5950-00-994-6594 is a Transformer,audio Frequency, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-00-994-6594?

1 possible match (shared part number, not a government interchangeability claim): 5950-01-058-4740. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-00-994-6594?

Key specifications for 5950-00-994-6594: Transformer Function: LINE; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 22 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-994-6594 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com