PartsTable TECHNICAL DATA SHEET
NSN 5950-00-962-9875Government record, cited

Transformer, Power5950-00-962-9875

NSN 5950-00-962-9875 · NIIN 009629875
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-962-9875 · 5950009629875 · NIIN 009629875 · 00-962-9875 · FSC 5950 Coils and Transformers
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 6.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: SLOT SINGLE GROUP
  • Winding Function and Quantity: 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
  • Winding Shielding Method: EXTERNAL INCLOSURE SINGLE COMPONENT
Identification
  • NSN: 5950-00-962-9875
  • NIIN: 009629875
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-962-9875, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-962-9875
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length6.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodSLOT SINGLE GROUP
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Winding Shielding MethodEXTERNAL INCLOSURE SINGLE COMPONENT
Winding Operating Current23.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage10.00 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity4 BINDING POST
Mounting Slot Width0.250 INCHES NOMINAL SINGLE GROUP IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5998-01-480-373863817-1 POSSIBLE MATCH
CIRCUIT CARD ASSEMBLY
Possible match (shared part number)Applied Systems Engineering Inc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
638-171 3/9 Design control — primary reference
Sherjor Inc
Related Parts
5998-01-480-3738POSSIBLE MATCH
CIRCUIT CARD ASSEMBLY
63817-1

Frequently Asked Questions

What is NSN 5950-00-962-9875?

NSN 5950-00-962-9875 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-00-962-9875?

1 possible match (shared part number, not a government interchangeability claim): 5998-01-480-3738. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-00-962-9875?

Key specifications for 5950-00-962-9875: Overall Height: 5.000 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 6.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 15 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-962-9875 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com