The Transformer,power, cataloged under National Stock Number 5950-00-957-3009, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Lockheed Martin Corporation Div Rms. Government technical data includes 24 specifications, cited from the U.S. Government catalog. The record lists 3 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-957-3009 |
| Primary Part Number | 2180992-2 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | Lockheed Martin Corporation Div Rms |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | OPEN |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | THREADED HOLE(S) SINGLE GROUP |
| Body Width | 1.750 INCHES MAXIMUM IN |
| Body Height | 2.250 INCHES MAXIMUM IN |
| Winding Function and Quantity | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| Nominal Thread Size | 0.164 INCHES SINGLE GROUP IN |
| Maximum Operating Temp | 130.0 CELSIUS DEGC |
| Body Length | 1.870 INCHES MAXIMUM IN |
| Winding Operating Current | 150.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Current | 1.25 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Current | 350.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Current | 1.75 AMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Thread Quantity Per Inch | 32 SINGLE GROUP |
| Winding Operating Voltage | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
| Winding Operating Voltage | 111.00 AC VOLTS NOMINAL AND 113.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Terminal Type and Quantity | 12 TAB, SOLDER LUG |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 43741 | Freed Transformer Co (USA) |
| 2180992-2 PRIMARY | Lockheed Martin Corporation Div Rms (USA) |
| PA6012 | Magnetika Inc (USA) |
| Reference | Meaning |
|---|---|
| 2180992-2 | 5/9 Secondary reference Lockheed Martin Corporation Dba Lockheed Martin Div Lockheed Martin |
| PA6012 | 5/9 Secondary reference U.S. Government activity |
NSN 5950-00-957-3009 is a Transformer,power, manufactured by Lockheed Martin Corporation Div Rms, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-00-957-3009 has 3 manufacturer part numbers on file: 43741 (Freed Transformer Co), 2180992-2 (Lockheed Martin Corporation Div Rms), PA6012 (Magnetika Inc).
1 possible match (shared part number, not a government interchangeability claim): 5930-01-138-9675. Verify interchangeability with system specifications before substitution.
Key specifications for 2180992-2: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: OPEN; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 24 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.