PartsTable TECHNICAL DATA SHEET
NSN 5950-00-878-9307Government record, cited

Transformer, Power5950-00-878-9307

NSN 5950-00-878-9307 · NIIN 008789307 · Part number 307844-2
Raytheon Company · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 37695
Government record, cited
NSN 5950-00-878-9307 — this item is cataloged by the U.S. Government under National Stock Number 5950-00-878-9307. Manufacturer of record part number: 307844-2.
Also searched as  5950-00-878-9307 · 5950008789307 · NIIN 008789307 · 00-878-9307 · FSC 5950 Coils and Transformers · CAGE 37695 · 307844-2 · 59T11C1832 · 8627289-2
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Transformer Winding Connection Type: WYE-WYE AND WYE-DELTA
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: PARTIALLY INCLOSED, DOUBLE SHELL
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: THREE PHASE TO THREE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED HOLE(S) SINGLE GROUP
  • Body Width: 1.807 INCHES MINIMUM AND 1.817 INCHES MAXIMUM IN
Identification
  • NSN: 5950-00-878-9307
  • NIIN: 008789307
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 307844-2
  • Manufacturer: Raytheon Company
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-878-9307, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company. Government technical data includes 21 specifications, cited from the U.S. Government catalog. The record lists 3 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-878-9307
Primary Part Number307844-2
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerRaytheon Company
StatusACTIVE
Transformer Winding Connection TypeWYE-WYE AND WYE-DELTA
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypePARTIALLY INCLOSED, DOUBLE SHELL
Center to Center Distance Between Mounting Facilities Parallel to Length1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipTHREE PHASE TO THREE PHASE SINGLE COMPONENT
Mounting MethodTHREADED HOLE(S) SINGLE GROUP
Body Width1.807 INCHES MINIMUM AND 1.817 INCHES MAXIMUM IN
Body Height3.281 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
Nominal Thread Size0.138 INCHES SINGLE GROUP IN
Body Length3.969 INCHES MAXIMUM IN
Winding Operating Current9.0 AMPERES DC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.373 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage103.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage13.80 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage151.30 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Terminal Type and Quantity12 TAB, SOLDER LUG
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
59T11C1832 Omega Associates, Inc. Dba Omega Associates Inc (USA)
307844-2 Omega Associates, Inc. Dba Omega Associates Inc (USA)
307844-2 PRIMARY Raytheon Company (USA)
Reference documents
ReferenceMeaning
8627289-2 7/2 Vendor item drawing reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-00-878-9307?

NSN 5950-00-878-9307 is a Transformer,power, manufactured by Raytheon Company, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-00-878-9307?

NSN 5950-00-878-9307 has 3 manufacturer part numbers on file: 59T11C1832 (Omega Associates, Inc. Dba Omega Associates Inc), 307844-2 (Omega Associates, Inc. Dba Omega Associates Inc), 307844-2 (Raytheon Company).

What are the specifications of 307844-2?

Key specifications for 307844-2: Transformer Winding Connection Type: WYE-WYE AND WYE-DELTA; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: PARTIALLY INCLOSED, DOUBLE SHELL; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-878-9307 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.