PartsTable TECHNICAL DATA SHEET
NSN 5950-00-855-3865Government record, cited

Transformer, Power5950-00-855-3865

NSN 5950-00-855-3865 · NIIN 008553865
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-855-3865 · 5950008553865 · NIIN 008553865 · 00-855-3865 · FSC 5950 Coils and Transformers · Y5987-3 · 362-7599 · 362-7599
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: OPEN
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.010 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: FLANGE SINGLE GROUP
  • Mounting Hole Diameter: 0.223 INCHES NOMINAL SINGLE GROUP IN
  • Winding Function and Quantity: 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
Identification
  • NSN: 5950-00-855-3865
  • NIIN: 008553865
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-855-3865, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-855-3865
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeOPEN
Center to Center Distance Between Mounting Facilities Parallel to Length3.010 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodFLANGE SINGLE GROUP
Mounting Hole Diameter0.223 INCHES NOMINAL SINGLE GROUP IN
Winding Function and Quantity1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
Maximum Operating Temp85.0 CELSIUS DEGC
Body Length4.125 INCHES NOMINAL IN
Winding Operating Current5.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current50.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current6.0 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current700.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width3.010 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage108.00 AC VOLTS NOMINAL AND 132.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage12.80 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage22.50 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage22.80 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage35.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Terminal Type and Quantity10 TAB, SOLDER LUG
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
Y5987-3 3/9 Design control — primary reference
Lockheed Martin Corporation Div Lockheed Martin Information Systems & Global Solutions
362-7599 7/2 Vendor item drawing reference
Lockheed Martin Corporation Dba Lockheed Martin Government
362-7599 5/9 Secondary reference
Lockheed Martin Corporation Div Lockheed Martin Information Systems & Global Solutions
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-00-855-3865?

NSN 5950-00-855-3865 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-00-855-3865?

Key specifications for 5950-00-855-3865: Overall Height: 4.155 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: OPEN; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.010 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 23 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-855-3865 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com