The Transformer,power, cataloged under National Stock Number 5950-00-819-1947, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 20 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-819-1947 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | HERMETICALLY SEALED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 3.003 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | THREADED STUD(S) SINGLE GROUP |
| Winding Function and Quantity | 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNALLY SHIELDED SINGLE COMPONENT |
| Nominal Thread Size | 0.250 INCHES SINGLE GROUP IN |
| Winding Operating Current | 8.0 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Current | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Current | 25.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 45.0 HERTZ MINIMUM AND 65.0 HERTZ MAXIMUM SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 2.777 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Voltage | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Voltage | 105.00 AC VOLTS NOMINAL AND 210.00 AC VOLTS NOMINAL AND 240.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 130.00 AC VOLTS NOMINAL AND 330.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| Terminal Type and Quantity | 13 TURRET |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 184-11-01-00 | 5/2 Secondary reference U.S. Government activity |
| T8334 | 3/9 Design control — primary reference Ptc Transformers |
NSN 5950-00-819-1947 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-00-819-1947: Overall Height: 4.288 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.003 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 20 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.