The Transformer,power, cataloged under National Stock Number 5950-00-817-7906, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-817-7906 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | PARTIALLY INCLOSED, DOUBLE SHELL |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 3.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| Body Width | 3.937 INCHES NOMINAL IN |
| Body Height | 4.625 INCHES NOMINAL IN |
| Winding Function and Quantity | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| Body Length | 4.500 INCHES NOMINAL IN |
| Winding Operating Current | 4.0 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Current | 3.0 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Current | 3.0 AMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| Winding Operating Current | 185.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| Winding Operating Voltage | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Voltage | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Voltage | 875.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Terminal Type and Quantity | 11 WIRE LEAD |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| K210T4101 | 5/9 Secondary reference U.S. Government activity |
| 24R15 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5950-00-817-7906 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-00-817-7906: Overall Height: 4.625 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: PARTIALLY INCLOSED, DOUBLE SHELL; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 23 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.