PartsTable TECHNICAL DATA SHEET
NSN 5950-00-800-0772Government record, cited

Transformer, Power5950-00-800-0772

NSN 5950-00-800-0772 · NIIN 008000772
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-800-0772 · 5950008000772 · NIIN 008000772 · 00-800-0772 · FSC 5950 Coils and Transformers · R5A · R5A
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP
  • Body Width: 2.625 INCHES NOMINAL IN
  • Body Height: 3.094 INCHES NOMINAL IN
Identification
  • NSN: 5950-00-800-0772
  • NIIN: 008000772
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-800-0772, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 18 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-800-0772
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodFLANGE AND UNTHREADED HOLE(S) SINGLE GROUP
Body Width2.625 INCHES NOMINAL IN
Body Height3.094 INCHES NOMINAL IN
Winding Function and Quantity1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
Body Length2.656 INCHES NOMINAL IN
Winding Operating Current2.7 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current65.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage6.30 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage600.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity8 WIRE LEAD
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
R5A 3/9 Design control — primary reference
Magnetek Inc Huntington Div
R5A C/1 Advisory reference — outside the item-of-supply concept
Magnetek Inc Lighting Products Group

Frequently Asked Questions

What is NSN 5950-00-800-0772?

NSN 5950-00-800-0772 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-00-800-0772?

Key specifications for 5950-00-800-0772: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 18 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-800-0772 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.