The Transformer,power, cataloged under National Stock Number 5950-00-648-6861, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is General Electric Company. Government technical data includes 19 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-648-6861 |
| Primary Part Number | B7485517 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | General Electric Company |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | HERMETICALLY SEALED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | UNTHREADED STUD SINGLE GROUP |
| Body Width | 3.062 INCHES NOMINAL IN |
| Body Height | 4.875 INCHES NOMINAL IN |
| Winding Function and Quantity | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| Body Length | 3.562 INCHES NOMINAL IN |
| Winding Operating Current | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Current | 99.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 54.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 115.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL AND 126.00 AC VOLTS NOMINAL AND 132.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 5.00 AC VOLTS NOMINAL AND 6.30 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Voltage | 750.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Terminal Type and Quantity | 11 SOLDER STUD |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| B7485517 | General Electric Company (USA) |
| Reference | Meaning |
|---|---|
| B7485517 | 3/9 Design control — primary reference General Electric Co Electronic Components Division of Electronic Atomic and Defense Systems Group |
NSN 5950-00-648-6861 is a Transformer,power, manufactured by General Electric Company, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-00-648-6861 has 1 manufacturer part number on file: B7485517 (General Electric Company).
Key specifications for B7485517: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 19 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.