Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 6.120 INCHES MINIMUM AND 6.130 INCHES MAXIMUM IN
  • Body Height: 5.120 INCHES MINIMUM AND 5.130 INCHES MAXIMUM IN
Identification
  • NSN: 5950-00-648-4532
  • NIIN: 006484532
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-648-4532, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 24 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-648-4532
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width6.120 INCHES MINIMUM AND 6.130 INCHES MAXIMUM IN
Body Height5.120 INCHES MINIMUM AND 5.130 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 6 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
Nominal Thread Size0.138 INCHES SINGLE GROUP IN
Body Length6.995 INCHES MINIMUM AND 7.005 INCHES MAXIMUM IN
Winding Operating Current2.5 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current1.25 AMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Current225.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating48.0 HERTZ MINIMUM AND 62.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage6.30 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Voltage5.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage500.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage6.30 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage105.00 AC VOLTS NOMINAL AND 110.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL AND 210.00 AC VOLTS NOMINAL AND 220.00 AC VOLTS NOMINAL AND 230.00 AC VOLTS NOMINAL AND 240.00 AC VOLTS NOMINAL AND 250.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity24 TAB, SOLDER LUG AND 3 STANDOFF, SOLDER LUG
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5331-01-376-6820240 POSSIBLE MATCH
O-RING
Possible match (shared part number)Parker-Hannifin Corporation Div O-Ring Division
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
TS240 5/9 Secondary reference
Magnetic Components Inc
SM-D-180211 3/2 Design control — primary reference
U.S. Government activity
Related Parts
5331-01-376-6820POSSIBLE MATCH
O-RING
240

Frequently Asked Questions

What is NSN 5950-00-648-4532?

NSN 5950-00-648-4532 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-00-648-4532?

1 possible match (shared part number, not a government interchangeability claim): 5331-01-376-6820. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-00-648-4532?

Key specifications for 5950-00-648-4532: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 24 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-648-4532 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com