The Transformer,power, cataloged under National Stock Number 5950-00-648-2959, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Freed Transformer Co. Government technical data includes 20 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-648-2959 |
| Primary Part Number | 24474 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | Freed Transformer Co |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| Body Width | 2.125 INCHES NOMINAL IN |
| Body Height | 5.000 INCHES NOMINAL IN |
| Mounting Hole Diameter | 0.312 INCHES NOMINAL SINGLE GROUP IN |
| Winding Function and Quantity | 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
| Body Length | 3.281 INCHES NOMINAL IN |
| Winding Operating Current | 110.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Current | 900.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Current | 9.8 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 50.0 HERTZ MINIMUM AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
| Winding Operating Voltage | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Voltage | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Voltage | 142.00 AC VOLTS NOMINAL AND 290.00 AC VOLTS NOMINAL AND 405.00 AC VOLTS NOMINAL AND 810.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Terminal Type and Quantity | 11 STANDOFF INSULATOR |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 24474 | Freed Transformer Co (USA) |
| Reference | Meaning |
|---|---|
| TR1256 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5950-00-648-2959 is a Transformer,power, manufactured by Freed Transformer Co, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-00-648-2959 has 1 manufacturer part number on file: 24474 (Freed Transformer Co).
1 possible match (shared part number, not a government interchangeability claim): 5325-01-372-3842. Verify interchangeability with system specifications before substitution.
Key specifications for 24474: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 20 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.