The Transformer,power, cataloged under National Stock Number 5950-00-648-0274, is classified within Federal Supply Class 5950 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is L3 Technologies, Inc. Div Communication Systems-East. Government technical data includes 22 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 5 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 9 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-648-0274 |
| Primary Part Number | RT348 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — No Item Name Available |
| Manufacturer | L3 Technologies, Inc. Div Communication Systems-East |
| Status | ACTIVE |
| Winding Operating Current | 125.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 4.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Current | 2.8 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Winding Function and Quantity | 2 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
| Winding Operating Voltage | 110.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Body Length | 5.062 INCHES NOMINAL IN |
| Body Width | 3.312 INCHES NOMINAL IN |
| Winding Shielding Method | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| Winding Operating Current | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Inclosure Type | FULLY INCLOSED |
| Winding Operating Voltage | 700.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Mounting Hole Diameter | 0.199 INCHES NOMINAL SINGLE GROUP IN |
| Body Height | 3.812 INCHES NOMINAL IN |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| Winding Operating Voltage | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Voltage | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| Terminal Type and Quantity | 13 WIRE LEAD |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| RT348 | Lockheed Martin Corporation Dba Lockheed Martin Div Lockheed Martin (USA) |
| P72364GP501 | Lockheed Martin Corporation Dba Lockheed Martin Div Lockheed Martin (USA) |
| RT348 PRIMARY | L3 Technologies, Inc. Div Communication Systems-East (USA) |
| P72364GP501 PRIMARY | L3 Technologies, Inc. Div Communication Systems-East (USA) |
| 30245 PRIMARY | Naval Ship Systems Command (USA) |
NSN 5950-00-648-0274 is a Transformer,power, manufactured by L3 Technologies, Inc. Div Communication Systems-East, classified under FSC 5950 (No Item Name Available). Status: active.
NSN 5950-00-648-0274 has 5 cross-referenced part numbers: RT348 (Lockheed Martin Corporation Dba Lockheed Martin Div Lockheed Martin), P72364GP501 (Lockheed Martin Corporation Dba Lockheed Martin Div Lockheed Martin), RT348 (L3 Technologies, Inc. Div Communication Systems-East), P72364GP501 (L3 Technologies, Inc. Div Communication Systems-East), 30245 (Naval Ship Systems Command).
There are 9 known substitutes for 5950-00-648-0274: 5963-00-070-1809, 3120-00-213-0825, 6640-00-290-6569 and 6 more. Verify interchangeability with system specifications before substitution.
Key specifications for RT348: Winding Operating Current: 125.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY; Center to Center Distance Between Mounting Facilities Parallel to Length: 4.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Winding Operating Current: 2.8 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY; Winding Function and Quantity: 2 PRIMARY AND 3 SECONDARY SINGLE COMPONENT. 22 total characteristics are documented in the Federal Logistics Information System.