PartsTable TECHNICAL DATA SHEET
NSN 5950-00-647-7136Government record, cited

Reactor5950-00-647-7136

NSN 5950-00-647-7136 · NIIN 006477136
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-647-7136 · 5950006477136 · NIIN 006477136 · 00-647-7136 · FSC 5950 Coils and Transformers · 17257A · 678-0499-000
Nearby stock numbers  ·
Features
  • Reactor — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Inductance Rating: 10.00 HENRY MAXIMUM SINGLE COMPONENT SINGLE WINDING
  • Body Width: 2.078 INCHES MAXIMUM IN
  • Body Height: 3.125 INCHES MAXIMUM IN
Identification
  • NSN: 5950-00-647-7136
  • NIIN: 006477136
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Reactor, cataloged under National Stock Number 5950-00-647-7136, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-647-7136
Item NameReactor
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Inductance Rating10.00 HENRY MAXIMUM SINGLE COMPONENT SINGLE WINDING
Body Width2.078 INCHES MAXIMUM IN
Body Height3.125 INCHES MAXIMUM IN
Nominal Thread Size0.138 INCHES SINGLE GROUP IN
Maximum Operating Temp105.0 CELSIUS DEGC
Body Length2.328 INCHES MAXIMUM IN
Winding Operating Current60.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
Rating MethodELECTRICAL SINGLE COMPONENT SINGLE WINDING
DC Resistance Rating in Ohms250.000 SINGLE COMPONENT SINGLE WINDING
Reliability IndicatorNOT ESTABLISHED
Winding Quantity1 SINGLE COMPONENT
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Thread Quantity Per Inch32 SINGLE GROUP
Terminal Type and Quantity2 STANDOFF, SOLDER LUG
Inductance TypeFIXED
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5945-00-761-582217-257 POSSIBLE MATCH
SOLENOID,ELECTRICAL
Possible match (shared part number)Detroit Coil Co.
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
17257A 3/9 Design control — primary reference
U.S. Government activity
678-0499-000 5/9 Secondary reference
Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems
Related Parts
5945-00-761-5822POSSIBLE MATCH
SOLENOID,ELECTRICAL
17-257

Frequently Asked Questions

What is NSN 5950-00-647-7136?

NSN 5950-00-647-7136 is a Reactor, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-00-647-7136?

1 possible match (shared part number, not a government interchangeability claim): 5945-00-761-5822. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-00-647-7136?

Key specifications for 5950-00-647-7136: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Mounting Method: THREADED STUD(S) SINGLE GROUP. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-647-7136 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com