PartsTable TECHNICAL DATA SHEET
NSN 5950-00-646-3253Government record, cited

Transformer, Power5950-00-646-3253

NSN 5950-00-646-3253 · NIIN 006463253 · Part number 8-5152
Magnetika Inc · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 15634
Government record, cited
NSN 5950-00-646-3253 — this item is cataloged by the U.S. Government under National Stock Number 5950-00-646-3253. Manufacturer of record part number: 8-5152.
Also searched as  5950-00-646-3253 · 5950006463253 · NIIN 006463253 · 00-646-3253 · FSC 5950 Coils and Transformers · CAGE 15634 · 8-5152
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP
  • Body Width: 3.750 INCHES NOMINAL IN
  • Body Height: 4.500 INCHES NOMINAL IN
Identification
  • NSN: 5950-00-646-3253
  • NIIN: 006463253
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 8-5152
  • Manufacturer: Magnetika Inc
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-646-3253, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Magnetika Inc. Government technical data includes 20 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-646-3253
Primary Part Number8-5152
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerMagnetika Inc
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodFLANGE AND UNTHREADED HOLE(S) SINGLE GROUP
Body Width3.750 INCHES NOMINAL IN
Body Height4.500 INCHES NOMINAL IN
Winding Function and Quantity2 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
Body Length3.750 INCHES NOMINAL IN
Winding Operating Current2.0 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current2.0 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current85.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage6.30 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage5.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
Winding Operating Voltage630.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Terminal Type and Quantity12 STANDOFF INSULATOR
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 3
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5962-01-265-8175 POSSIBLE MATCH
MICROCIRCUIT,MEMORY
Possible match (shared part number)
5962-01-266-1459 POSSIBLE MATCH
MICROCIRCUIT,MEMORY
Possible match (shared part number)
6105-01-504-695385152 POSSIBLE MATCH
MOTOR,ALTERNATING CURRENT
Possible match (shared part number)American Permanent Ware Company Dba Apw/wyott Foodservice Eqp Co
Cross-Reference Index
Part NumberManufacturer
8-5152 PRIMARY Magnetika Inc (USA)
Reference documents
ReferenceMeaning
8-5152 5/9 Secondary reference
U.S. Government activity
Related Parts
5962-01-265-8175POSSIBLE MATCH
MICROCIRCUIT,MEMORY
5962-01-266-1459POSSIBLE MATCH
MICROCIRCUIT,MEMORY
6105-01-504-6953POSSIBLE MATCH
MOTOR,ALTERNATING CURRENT
85152

Frequently Asked Questions

What is NSN 5950-00-646-3253?

NSN 5950-00-646-3253 is a Transformer,power, manufactured by Magnetika Inc, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-00-646-3253?

NSN 5950-00-646-3253 has 1 manufacturer part number on file: 8-5152 (Magnetika Inc).

What NSN replaces 5950-00-646-3253?

3 possible matches (shared part number, not a government interchangeability claim): 5962-01-265-8175, 5962-01-266-1459, 6105-01-504-6953. Verify interchangeability with system specifications before substitution.

What are the specifications of 8-5152?

Key specifications for 8-5152: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 20 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-646-3253 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com