The Reactor, cataloged under National Stock Number 5950-00-645-1094, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Northrop Grumman Systems Corporation. Government technical data includes 17 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-645-1094 |
| Primary Part Number | 90C12REV3PC7 |
| Item Name | Reactor |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | Northrop Grumman Systems Corporation |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | OPEN |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Mounting Method | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| Inductance Rating | 49.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
| Body Width | 2.375 INCHES NOMINAL IN |
| Body Height | 2.312 INCHES NOMINAL IN |
| Body Length | 2.500 INCHES NOMINAL IN |
| Winding Operating Current | 640.0 MILLIAMPERES DC MINIMUM SINGLE COMPONENT SINGLE WINDING |
| Rating Method | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
| DC Resistance Rating in Ohms | 5.200 SINGLE COMPONENT SINGLE WINDING |
| Reliability Indicator | NOT ESTABLISHED |
| Winding Quantity | 1 SINGLE COMPONENT |
| Frequency Rating | 360.0 HERTZ NOMINAL SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 1.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Terminal Type and Quantity | 2 TAB, SOLDER LUG |
| Inductance Type | FIXED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 90C12REV3PC7 PRIMARY | Northrop Grumman Systems Corporation (USA) |
| Reference | Meaning |
|---|---|
| 6104-3151151PC48SH1 | 3/2 Design control — primary reference U.S. Government activity |
| 6308-3158517PC16 | 3/2 Design control — primary reference U.S. Government activity |
| 6104-3151151ITEM12 | 3/2 Design control — primary reference U.S. Government activity |
| 6308-3158517PCSPITEM7 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5950-00-645-1094 is a Reactor, manufactured by Northrop Grumman Systems Corporation, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-00-645-1094 has 1 manufacturer part number on file: 90C12REV3PC7 (Northrop Grumman Systems Corporation).
Key specifications for 90C12REV3PC7: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: OPEN; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Mounting Method: FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP. 17 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.