The Transformer,power, cataloged under National Stock Number 5950-00-617-4136, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-617-4136 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | OPEN |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| Body Width | 2.625 INCHES NOMINAL IN |
| Body Height | 2.875 INCHES NOMINAL IN |
| Winding Function and Quantity | 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| Body Length | 2.750 INCHES NOMINAL IN |
| Winding Operating Current | 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Current | 300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Current | 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 320.0 HERTZ MINIMUM AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 1.800 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 1.15 AC KILOVOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Voltage | 271.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Voltage | 275.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Terminal Type and Quantity | 8 TAB, SOLDER LUG |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 7436689P1 | 3/9 Design control — primary reference U.S. Government activity |
| A11011 | 5/9 Secondary reference Te Connectivity Networks, Inc. Div Adc Telecommunications Sales, Inc. |
| 7436689P1 | 5/9 Secondary reference General Electric Company |
| 7436689P1 | 5/2 Secondary reference U.S. Government activity |
| 7436689PT1 | 5/9 Secondary reference General Electric Company |
| 7436689PT1 | 5/9 Secondary reference U.S. Government activity |
NSN 5950-00-617-4136 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
1 possible match (shared part number, not a government interchangeability claim): 8455-01-673-9015. Verify interchangeability with system specifications before substitution.
Key specifications for 5950-00-617-4136: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: OPEN; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 21 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.