PartsTable TECHNICAL DATA SHEET
NSN 5950-00-600-1666Government record, cited

Transformer, Power5950-00-600-1666

NSN 5950-00-600-1666 · NIIN 006001666 · Part number 39927
Freed Transformer Co · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 73386
Government record, cited
NSN 5950-00-600-1666 — this item is cataloged by the U.S. Government under National Stock Number 5950-00-600-1666. Manufacturer of record part number: 39927.
Also searched as  5950-00-600-1666 · 5950006001666 · NIIN 006001666 · 00-600-1666 · FSC 5950 Coils and Transformers · CAGE 73386 · 39927 · 9T35Y488 · SM-C-331814 · 39957
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 4.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 4.310 INCHES NOMINAL IN
  • Body Height: 6.810 INCHES NOMINAL IN
Identification
  • NSN: 5950-00-600-1666
  • NIIN: 006001666
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 39927
  • Manufacturer: Freed Transformer Co
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-600-1666, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Freed Transformer Co. Government technical data includes 20 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-600-1666
Primary Part Number39927
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerFreed Transformer Co
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length4.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width4.310 INCHES NOMINAL IN
Body Height6.810 INCHES NOMINAL IN
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
Nominal Thread Size0.250 INCHES SINGLE GROUP IN
Body Length5.060 INCHES NOMINAL IN
Winding Operating Current106.0 MILLIAMPERES AC MAXIMUM AND 425.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width3.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Thread Quantity Per Inch20 SINGLE GROUP
Winding Operating Voltage115.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL AND 126.00 AC VOLTS NOMINAL AND 132.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage450.00 AC VOLTS NOMINAL AND 900.00 AC VOLTS NOMINAL AND 1.816 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Terminal Type and Quantity10 SOLDER STUD
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 3
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
6680-01-081-779939927 POSSIBLE MATCH
TRANSMITTER,LIQUID QUANTITY
Possible match (shared part number)Setra Systems, Inc. Dba Gems Sensors
5305-01-600-310539957 POSSIBLE MATCH
SCREW,CAP,SOCKET HEAD
Possible match (shared part number)Fastenal Company Dba Fastenal Co
5305-01-600-323539927 POSSIBLE MATCH
SCREW,CAP,SOCKET HEAD
Possible match (shared part number)Fastenal Company Dba Fastenal Co
Cross-Reference Index
Part NumberManufacturer
39927 Freed Transformer Co (USA)
39957 Freed Transformer Co (USA)
Reference documents
ReferenceMeaning
9T35Y488 5/9 Secondary reference
General Electric Co Specialty Transformer Dept
SM-C-331814 3/2 Design control — primary reference
U.S. Government activity
Related Parts
6680-01-081-7799POSSIBLE MATCH
TRANSMITTER,LIQUID QUANTITY
39927
5305-01-600-3105POSSIBLE MATCH
SCREW,CAP,SOCKET HEAD
39957
5305-01-600-3235POSSIBLE MATCH
SCREW,CAP,SOCKET HEAD
39927

Frequently Asked Questions

What is NSN 5950-00-600-1666?

NSN 5950-00-600-1666 is a Transformer,power, manufactured by Freed Transformer Co, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-00-600-1666?

NSN 5950-00-600-1666 has 2 manufacturer part numbers on file: 39927 (Freed Transformer Co), 39957 (Freed Transformer Co).

What NSN replaces 5950-00-600-1666?

3 possible matches (shared part number, not a government interchangeability claim): 6680-01-081-7799, 5305-01-600-3105, 5305-01-600-3235. Verify interchangeability with system specifications before substitution.

What are the specifications of 39927?

Key specifications for 39927: Overall Height: 7.450 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 4.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 20 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-600-1666 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com