The Transformer,power, cataloged under National Stock Number 5950-00-553-7230, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-553-7230 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Inclosure Type | PARTIALLY INCLOSED, DOUBLE SHELL |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | THREADED BUSHING SINGLE GROUP |
| Body Width | 3.275 INCHES NOMINAL IN |
| Body Height | 2.875 INCHES NOMINAL IN |
| Winding Function and Quantity | 2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| Nominal Thread Size | 0.138 INCHES SINGLE GROUP IN |
| Body Length | 3.574 INCHES NOMINAL IN |
| Winding Operating Current | 1.2 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Current | 3.8 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| Thread Quantity Per Inch | 32 SINGLE GROUP |
| Winding Operating Voltage | 10.00 AC VOLTS NOMINAL AND 20.00 AC VOLTS NOMINAL AND 27.50 AC VOLTS NOMINAL AND 30.00 AC VOLTS NOMINAL AND 40.00 AC VOLTS NOMINAL AND 90.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Voltage | 5.00 AC VOLTS NOMINAL AND 10.00 AC VOLTS NOMINAL AND 16.00 AC VOLTS NOMINAL AND 20.00 AC VOLTS NOMINAL AND 27.50 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Voltage | 52.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST PRIMARY |
| Winding Operating Voltage | 60.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND PRIMARY |
| Terminal Type and Quantity | 18 WIRE LEAD |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 9801-84 | 3/9 Design control — primary reference L3 Technologies, Inc. Dba Insight Technology Division Div Insight Technology Division |
NSN 5950-00-553-7230 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-00-553-7230: Inclosure Type: PARTIALLY INCLOSED, DOUBLE SHELL; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT; Mounting Method: THREADED BUSHING SINGLE GROUP; Body Width: 3.275 INCHES NOMINAL IN. 19 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.