PartsTable TECHNICAL DATA SHEET
NSN 5950-00-534-5193Government record, cited

Transformer Assembly5950-00-534-5193

NSN 5950-00-534-5193 · NIIN 005345193 · Part number 1244521
Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 10001
Government record, cited
NSN 5950-00-534-5193 — this item is cataloged by the U.S. Government under National Stock Number 5950-00-534-5193. Manufacturer of record part number: 1244521.
Also searched as  5950-00-534-5193 · 5950005345193 · NIIN 005345193 · 00-534-5193 · FSC 5950 Coils and Transformers · CAGE 10001 · 1244521 · 188C239
Nearby stock numbers  ·
Features
  • Transformer Assembly — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.620 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 2.835 INCHES MAXIMUM IN
  • Body Height: 4.000 INCHES MAXIMUM IN
Identification
  • NSN: 5950-00-534-5193
  • NIIN: 005345193
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 1244521
  • Manufacturer: Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier
General Description

The Transformer Assembly, cataloged under National Stock Number 5950-00-534-5193, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-534-5193
Primary Part Number1244521
Item NameTransformer Assembly
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerNavair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length2.620 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE ALL COMPONENTS
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width2.835 INCHES MAXIMUM IN
Body Height4.000 INCHES MAXIMUM IN
Maximum Transformer Power Rating90.0 VOLT-AMPERE FIRST COMPONENT
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY ALL COMPONENTS
Features ProvidedW/RECTIFIER
Nominal Thread Size0.190 INCHES SINGLE GROUP IN
Maximum Operating Temp120.0 CELSIUS DEGC
Body Length3.550 INCHES NOMINAL IN
Winding Operating Current150.0 MILLIAMPERES AC MAXIMUM SECOND COMPONENT SINGLE SECONDARY
Winding Operating Current782.0 MILLIAMPERES AC MAXIMUM FIRST COMPONENT SINGLE PRIMARY
Rating MethodELECTRICAL ALL COMPONENTS SINGLE SECONDARY
Rating MethodELECTRICAL ALL COMPONENTS SINGLE PRIMARY
DC Resistance Rating in Ohms0.100 FIRST COMPONENT SINGLE PRIMARY
DC Resistance Rating in Ohms0.400 SECOND COMPONENT SINGLE SECONDARY
DC Resistance Rating in Ohms16.000 FIRST COMPONENT SINGLE SECONDARY
DC Resistance Rating in Ohms2.000 SECOND COMPONENT SINGLE PRIMARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL ALL COMPONENTS
Center to Center Distance Between Mounting Facilities Parallel to Width2.112 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage115.00 AC VOLTS NOMINAL FIRST COMPONENT SINGLE PRIMARY
Winding Operating Voltage20.00 AC VOLTS NOMINAL SECOND COMPONENT SINGLE SECONDARY
Winding Operating Voltage280.00 AC VOLTS NOMINAL SECOND COMPONENT SINGLE PRIMARY
Winding Operating Voltage350.00 AC VOLTS NOMINAL FIRST COMPONENT SINGLE SECONDARY
Terminal Type and Quantity13 WIRE LEAD
Thread Series DesignatorUNF SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
1244521 PRIMARY Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier (USA)
188C239 Lockheed Martin Corporation Div Rms (USA)
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-00-534-5193?

NSN 5950-00-534-5193 is a Transformer Assembly, manufactured by Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-00-534-5193?

NSN 5950-00-534-5193 has 2 manufacturer part numbers on file: 1244521 (Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier), 188C239 (Lockheed Martin Corporation Div Rms).

What are the specifications of 1244521?

Key specifications for 1244521: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.620 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-534-5193 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com