The Transformer,power, cataloged under National Stock Number 5950-00-450-3435, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 26 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-450-3435 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Transformer Winding Connection Type | DELTA-WYE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | THREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| Mounting Method | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| Body Width | 2.250 INCHES MAXIMUM IN |
| Body Height | 1.160 INCHES MAXIMUM IN |
| Mounting Hole Diameter | 0.165 INCHES MINIMUM AND 0.175 INCHES MAXIMUM SINGLE GROUP IN |
| Winding Function and Quantity | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| Maximum Operating Temp | 155.0 CELSIUS DEGC |
| Body Length | 2.820 INCHES MAXIMUM IN |
| Winding Operating Current | 15.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Current | 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Current | 10.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Current | 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 1067.00 AC VOLTS MINIMUM AND 1133.00 AC VOLTS MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Voltage | 113.00 AC VOLTS MINIMUM AND 195.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 1891.50 AC VOLTS MINIMUM AND 1008.50 AC VOLTS MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Voltage | 87.30 AC VOLTS MINIMUM AND 92.70 AC VOLTS MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| Winding Operating Voltage | 87.30 AC VOLTS MINIMUM AND 92.70 AC VOLTS MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Terminal Type and Quantity | 14 TURRET |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 243154P2 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5950-00-450-3435 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-00-450-3435: Transformer Winding Connection Type: DELTA-WYE; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 26 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.