The Transformer,power, cataloged under National Stock Number 5950-00-442-2113, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Us Army Aviation and Missile Command. Government technical data includes 22 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-442-2113 |
| Primary Part Number | 11150076 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | Us Army Aviation and Missile Command |
| Status | ACTIVE |
| Transformer Winding Connection Type | DELTA-WYE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| Mounting Method | THREADED STUD(S) SINGLE GROUP |
| Body Width | 4.450 INCHES NOMINAL IN |
| Winding Function and Quantity | 3 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| Nominal Thread Size | 0.250 INCHES SINGLE GROUP IN |
| Maximum Operating Temp | 70.0 CELSIUS DEGC |
| Body Length | 5.750 INCHES NOMINAL IN |
| Winding Operating Current | 9.9 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 204.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD PRIMARY |
| Winding Operating Voltage | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND PRIMARY |
| Winding Operating Voltage | 213.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST PRIMARY |
| Winding Operating Voltage | 25.30 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
| Terminal Type and Quantity | 6 THREADED STUD AND 13 TURRET |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 11150076 PRIMARY | Us Army Aviation and Missile Command (USA) |
NSN 5950-00-442-2113 is a Transformer,power, manufactured by Us Army Aviation and Missile Command, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-00-442-2113 has 1 manufacturer part number on file: 11150076 (Us Army Aviation and Missile Command).
Key specifications for 11150076: Overall Height: 4.875 INCHES NOMINAL IN; Transformer Winding Connection Type: DELTA-WYE; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED. 22 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.