PartsTable TECHNICAL DATA SHEET
NSN 5950-00-422-1448Government record, cited

Transformer, Power5950-00-422-1448

NSN 5950-00-422-1448 · NIIN 004221448
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-422-1448 · 5950004221448 · NIIN 004221448 · 00-422-1448 · FSC 5950 Coils and Transformers · 300064-1 · BX-5074B
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 2.690 INCHES NOMINAL IN
  • Body Height: 2.310 INCHES NOMINAL IN
Identification
  • NSN: 5950-00-422-1448
  • NIIN: 004221448
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-422-1448, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 24 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-422-1448
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length2.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width2.690 INCHES NOMINAL IN
Body Height2.310 INCHES NOMINAL IN
Winding Function and Quantity1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
Nominal Thread Size0.164 INCHES SINGLE GROUP IN
Body Length3.720 INCHES NOMINAL IN
Winding Operating Current60.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current1004.0 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Test Data Document93024-300064-1 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage6.30 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage1.075 AC KILOVOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage112.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Terminal Type and Quantity8 SOLDER STUD
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
300064-1 3/9 Design control — primary reference
U.S. Government activity
BX-5074B 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-00-422-1448?

NSN 5950-00-422-1448 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-00-422-1448?

Key specifications for 5950-00-422-1448: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 24 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-422-1448 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com