PartsTable TECHNICAL DATA SHEET
NSN 5950-00-421-5774Government record, cited

Transformer, Power5950-00-421-5774

NSN 5950-00-421-5774 · NIIN 004215774
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-421-5774 · 5950004215774 · NIIN 004215774 · 00-421-5774 · FSC 5950 Coils and Transformers · ST28698 · 405D1142
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 2 SINGLE GROUP
  • Inclosure Type: PARTIALLY INCLOSED, DOUBLE SHELL
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP
  • Body Width: 2.030 INCHES NOMINAL IN
  • Body Height: 2.400 INCHES NOMINAL IN
  • Mounting Hole Diameter: 0.190 INCHES NOMINAL SINGLE GROUP IN
Identification
  • NSN: 5950-00-421-5774
  • NIIN: 004215774
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-421-5774, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-421-5774
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity2 SINGLE GROUP
Inclosure TypePARTIALLY INCLOSED, DOUBLE SHELL
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodFLANGE AND UNTHREADED HOLE(S) SINGLE GROUP
Body Width2.030 INCHES NOMINAL IN
Body Height2.400 INCHES NOMINAL IN
Mounting Hole Diameter0.190 INCHES NOMINAL SINGLE GROUP IN
Winding Function and Quantity1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Distance Between Mounting Facility Centers2.580 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Body Length2.060 INCHES NOMINAL IN
Winding Operating Current80.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current400.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating57.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT
Winding Operating Voltage22.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage56.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Terminal Type and Quantity9 TAB, SOLDER LUG
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
ST28698 3/9 Design control — primary reference
U.S. Government activity
405D1142 5/9 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-00-421-5774?

NSN 5950-00-421-5774 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-00-421-5774?

Key specifications for 5950-00-421-5774: Mounting Facility Quantity: 2 SINGLE GROUP; Inclosure Type: PARTIALLY INCLOSED, DOUBLE SHELL; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT; Mounting Method: FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP. 19 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-421-5774 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com