PartsTable TECHNICAL DATA SHEET
JULY 2026Technical Data Sheet

373120Transformer,power

Raytheon Company Dba Raytheon Co · NSN 5950-00-419-7542 · FSC 5950 · No Item Name Available
Verified by PartsTable
NSN 5950-00-419-7542 — this item is cataloged by the U.S. Government under National Stock Number 5950-00-419-7542. Primary manufacturer part number: 373120.
Features
  • Transformer,power — FSC 5950
  • Inclosure Type: FULLY INCLOSED
  • Winding Operating Voltage: 60.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
  • Winding Operating Current: 2.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
  • Winding Shielding Method: INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
  • Center to Center Distance Between Mounting Facilities Parallel to Width: 0.940 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Winding Operating Voltage: 180.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
  • Frequency Rating: 35.0 KILOHERTZ NOMINAL SINGLE COMPONENT
Applications
  • Industrial maintenance and repair
  • Government and military logistics
  • Equipment overhaul and refurbishment
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-419-7542, is classified within Federal Supply Class 5950 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Raytheon Company Dba Raytheon Co. Government technical data includes 21 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 4 manufacturers, enabling identification through both NSN and commercial part number lookups. 7 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-419-7542
Primary Part Number373120
Item NameTransformer,power
FSC / FSG5950 / 59 — No Item Name Available
ManufacturerRaytheon Company Dba Raytheon Co
StatusACTIVE
Inclosure TypeFULLY INCLOSED
Winding Operating Voltage60.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Current2.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width0.940 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage180.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Frequency Rating35.0 KILOHERTZ NOMINAL SINGLE COMPONENT
Winding Operating Current16.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
Reliability IndicatorNOT ESTABLISHED
Body Length1.312 INCHES MAXIMUM IN
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Terminal Type and Quantity6 PIN
Center to Center Distance Between Mounting Facilities Parallel to Length0.940 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Mounting MethodTHREADED HOLE(S) SINGLE GROUP
Body Width1.312 INCHES MAXIMUM IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Thread Quantity Per Inch40 SINGLE GROUP
Body Height1.125 INCHES MAXIMUM IN
Mounting Facility Quantity4 SINGLE GROUP
Nominal Thread Size0.112 INCHES SINGLE GROUP IN
Lifecycle & Compliance
Acquisition StatusACTIVE
HAZMATNo
Verified Substitutes 7
5310-00-496-416916-627 INTERCHANGEABLE
Washer,flat
Dresser Industries Inc Leroi Div
5365-00-512-1746 INTERCHANGEABLE
Spacer,ring
5950-00-764-09251662-7 INTERCHANGEABLE
Coil,radio Frequency
Caddell Burns Manufacturing Co Inc
5905-00-799-14991-6627 INTERCHANGEABLE
Resistor,fixed,wire Wound
Bi Technologies Corporation Div Bi Technologies Corp.
5420-00-816-5647 INTERCHANGEABLE
Cap Assembly Hydrau
5950-01-086-004716627 INTERCHANGEABLE
Transformer,power
Drs Signal Solutions, Inc.
6515-01-591-3239218.110 INTERCHANGEABLE
Screw,bone
Depuy Synthes Sales Inc Dba Depuy Synthes Trauma Div Depuy Synthes Sales, Inc., D/b/a Depuy Synthes Trauma
Cross-Reference Index
Part NumberManufacturer
373120 Raytheon Company (USA)
373120 Raytheon Company Div Corp (USA)
16627 Robert M. Hadley Company, Inc. (USA)
373120 PRIMARY Raytheon Company Dba Raytheon Co (USA)
Related Parts
5310-00-496-4169INTERCHANGEABLE
WASHER,FLAT
16-627
5365-00-512-1746INTERCHANGEABLE
SPACER,RING
5950-00-764-0925INTERCHANGEABLE
COIL,RADIO FREQUENCY
1662-7
5905-00-799-1499INTERCHANGEABLE
RESISTOR,FIXED,WIRE WOUND
1-6627
5420-00-816-5647INTERCHANGEABLE
CAP ASSEMBLY HYDRAU
5950-01-086-0047INTERCHANGEABLE
TRANSFORMER,POWER
16627
6515-01-591-3239INTERCHANGEABLE
SCREW,BONE
218.110

Frequently Asked Questions

What is NSN 5950-00-419-7542?

NSN 5950-00-419-7542 is a Transformer,power, manufactured by Raytheon Company Dba Raytheon Co, classified under FSC 5950 (No Item Name Available). Status: active.

What are the part numbers for NSN 5950-00-419-7542?

NSN 5950-00-419-7542 has 4 cross-referenced part numbers: 373120 (Raytheon Company), 373120 (Raytheon Company Div Corp), 16627 (Robert M. Hadley Company, Inc.), 373120 (Raytheon Company Dba Raytheon Co).

What NSN replaces 5950-00-419-7542?

There are 7 known substitutes for 5950-00-419-7542: 5310-00-496-4169, 5365-00-512-1746, 5950-00-764-0925 and 4 more. Verify interchangeability with system specifications before substitution.

What are the specifications of 373120?

Key specifications for 373120: Inclosure Type: FULLY INCLOSED; Winding Operating Voltage: 60.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY; Winding Operating Current: 2.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY; Winding Shielding Method: INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT. 22 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com