The Transformer,power, cataloged under National Stock Number 5950-00-419-7540, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company Dba Raytheon Co. Government technical data includes 19 specifications, cited from the U.S. Government catalog. The record lists 5 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 10 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-419-7540 |
| Primary Part Number | 370034-1 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | Raytheon Company Dba Raytheon Co |
| Status | ACTIVE |
| Mounting Facility Quantity | 2 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | THREADED HOLE(S) SINGLE GROUP |
| Body Width | 0.950 INCHES NOMINAL IN |
| Body Height | 0.800 INCHES NOMINAL IN |
| Winding Function and Quantity | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| Distance Between Mounting Facility Centers | 0.660 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Nominal Thread Size | 0.112 INCHES SINGLE GROUP IN |
| Body Length | 0.950 INCHES NOMINAL IN |
| Winding Operating Current | 400.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| Thread Quantity Per Inch | 40 SINGLE GROUP |
| Winding Operating Voltage | 230.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| Winding Operating Voltage | 7.00 AC VOLTS NOMINAL AND 13.00 AC VOLTS NOMINAL AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Terminal Type and Quantity | 7 PIN |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 163464 | Raytheon Company (USA) |
| K6217 | Keytronics, Inc. Div Api Technologies Corp- Magnetics (USA) |
| 370034-1 | Raytheon Company (USA) |
| 163464 | Raytheon Company Dba Raytheon Co (USA) |
| 370034-1 PRIMARY | Raytheon Company Dba Raytheon Co (USA) |
| Reference | Meaning |
|---|---|
| 16167 | 5/1 Secondary reference Robert M. Hadley Company, Inc. |
| 370034-1 | 5/9 Secondary reference Raytheon Company Div Corp |
| 13164 | 5/9 Secondary reference U.S. Government activity |
| BX-9120 | 5/2 Secondary reference U.S. Government activity |
| 163464 | 5/9 Secondary reference Raytheon Company Div Corp |
| 840539 | 5/2 Secondary reference U.S. Government activity |
NSN 5950-00-419-7540 is a Transformer,power, manufactured by Raytheon Company Dba Raytheon Co, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-00-419-7540 has 5 manufacturer part numbers on file: 163464 (Raytheon Company), K6217 (Keytronics, Inc. Div Api Technologies Corp- Magnetics), 370034-1 (Raytheon Company), 163464 (Raytheon Company Dba Raytheon Co), 370034-1 (Raytheon Company Dba Raytheon Co).
10 possible matches (shared part number, not a government interchangeability claim): 5340-00-509-4753, 3040-00-734-3047, 3020-00-738-8491. Verify interchangeability with system specifications before substitution.
Key specifications for 370034-1: Mounting Facility Quantity: 2 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT; Mounting Method: THREADED HOLE(S) SINGLE GROUP. 19 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.