PartsTable TECHNICAL DATA SHEET
NSN 5950-00-419-4370Government record, cited

Transformer, Power5950-00-419-4370

NSN 5950-00-419-4370 · NIIN 004194370
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-419-4370 · 5950004194370 · NIIN 004194370 · 00-419-4370 · FSC 5950 Coils and Transformers · TF4RX01GA · 573A499BFPC1
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Winding Power Rating: 25.0 VOLTS-AMPERES SINGLE COMPONENT ALL PRIMARY
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 2.380 INCHES NOMINAL IN
Identification
  • NSN: 5950-00-419-4370
  • NIIN: 004194370
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-419-4370, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-419-4370
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Power Rating25.0 VOLTS-AMPERES SINGLE COMPONENT ALL PRIMARY
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width2.380 INCHES NOMINAL IN
Body Height3.810 INCHES NOMINAL IN
Criticality Code JustificationZZZY
Winding Function and Quantity4 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
Nominal Thread Size0.164 INCHES SINGLE GROUP IN
Body Length2.750 INCHES NOMINAL IN
Reliability IndicatorNOT ESTABLISHED
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Thread Quantity Per Inch32 SINGLE GROUP
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
Winding Operating Voltage57.50 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
Terminal Type and Quantity12 PIN
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Reference Number Differentiating CharacteristicsMATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTER ACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeY
⇄ Related Items 2
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5950-00-869-122827F09 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)Thordarson Inc
5950-01-058-0177 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
TF4RX01GA 5/9 Secondary reference
U.S. Government activity
573A499BFPC1 3/1 Design control — primary reference
General Electric Company Dba Ge
Related Parts
5950-00-869-1228POSSIBLE MATCH
TRANSFORMER,POWER
27F09
5950-01-058-0177POSSIBLE MATCH
TRANSFORMER,POWER

Frequently Asked Questions

What is NSN 5950-00-419-4370?

NSN 5950-00-419-4370 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-00-419-4370?

2 possible matches (shared part number, not a government interchangeability claim): 5950-00-869-1228, 5950-01-058-0177. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-00-419-4370?

Key specifications for 5950-00-419-4370: Overall Height: 4.210 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-419-4370 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com