The Transformer,power, cataloged under National Stock Number 5950-00-403-4034, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company Div Rmd Strategic. Government technical data includes 18 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-403-4034 |
| Primary Part Number | 722728-1 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | Raytheon Company Div Rmd Strategic |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| Mounting Method | FLANGE AND SLOT SINGLE GROUP |
| Body Width | 1.380 INCHES NOMINAL IN |
| Body Height | 2.380 INCHES NOMINAL IN |
| Winding Function and Quantity | 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| Body Length | 2.880 INCHES NOMINAL IN |
| Winding Operating Current | 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 1.265 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 109.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 121.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 20.70 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| Terminal Type and Quantity | 16 TAB, SOLDER LUG |
| Mounting Slot Width | 0.160 INCHES NOMINAL SINGLE GROUP IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
NSN 5950-00-403-4034 is a Transformer,power, manufactured by Raytheon Company Div Rmd Strategic, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-00-403-4034 has 2 manufacturer part numbers on file: 474 (Standard Industries), 722728-1 (Raytheon Company Div Rmd Strategic).
Key specifications for 722728-1: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: THREE PHASE TO THREE PHASE SINGLE COMPONENT. 18 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.