PartsTable TECHNICAL DATA SHEET
NSN 5950-00-402-9148Government record, cited

Transformer, Power5950-00-402-9148

NSN 5950-00-402-9148 · NIIN 004029148
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-402-9148 · 5950004029148 · NIIN 004029148 · 00-402-9148 · FSC 5950 Coils and Transformers · LHST6-24A · 501528
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: OPEN
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: FLANGE AND SLOT SINGLE GROUP
  • Body Width: 5.125 INCHES MAXIMUM IN
  • Body Height: 4.438 INCHES MAXIMUM IN
Identification
  • NSN: 5950-00-402-9148
  • NIIN: 004029148
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-402-9148, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-402-9148
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeOPEN
Center to Center Distance Between Mounting Facilities Parallel to Length4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodFLANGE AND SLOT SINGLE GROUP
Body Width5.125 INCHES MAXIMUM IN
Body Height4.438 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
Maximum Operating Temp75.0 CELSIUS DEGC
Body Length5.312 INCHES MAXIMUM IN
Winding Operating Current2.6 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current22.3 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage17.60 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage35.20 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage44.60 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Terminal Type and Quantity11 TAB, SOLDER LUG
Mounting Slot Width0.188 INCHES NOMINAL SINGLE GROUP IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
LHST6-24A 5/9 Secondary reference
Systron-Donner Corp Microwave/instrument Div
501528 3/9 Design control — primary reference
Systron-Donner Corp Microwave/instrument Div
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-00-402-9148?

NSN 5950-00-402-9148 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-00-402-9148?

Key specifications for 5950-00-402-9148: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: OPEN; Center to Center Distance Between Mounting Facilities Parallel to Length: 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 23 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-402-9148 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com