The Transformer,current, cataloged under National Stock Number 5950-00-369-1358, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Ward Leonard Ct Llc. Government technical data includes 11 specifications, cited from the U.S. Government catalog. The record lists 4 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-369-1358 |
| Primary Part Number | 50065-3CPCF5 |
| Item Name | Transformer,current |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | Ward Leonard Ct Llc |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 FIRST GROUP |
| Inclosure Type | OPEN |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Body Width | 6.125 INCHES NOMINAL IN |
| Body Height | 5.875 INCHES NOMINAL IN |
| Mounting Hole Diameter | 0.406 INCHES NOMINAL SINGLE GROUP IN |
| Winding Function and Quantity | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| Maximum Operating Temp | 50.0 CELSIUS DEGC |
| Body Length | 6.406 INCHES NOMINAL IN |
| Reliability Indicator | NOT ESTABLISHED |
| Terminal Type and Quantity | 2 BUS (BAR) CONDUCTOR AND 1 TERMINAL BLOCK W/SCREWS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 50065-3CPCF5 | Ward Leonard Ct Llc (USA) |
| 50064APC1T04 | Ward Leonard Ct Llc (USA) |
| 16535-67-1 | Ward Leonard Ct Llc (USA) |
| 50083-1ASH1PCF2 | Ward Leonard Ct Llc (USA) |
| Reference | Meaning |
|---|---|
| 50064C--1TO4 PT NO 16535 67-1 | C/1 Advisory reference — outside the item-of-supply concept Ward Leonard Ct Llc |
| 6202-3104377PC1T04 | 3/2 Design control — primary reference U.S. Government activity |
| 6303-1194724PCF2 | 5/2 Secondary reference U.S. Government activity |
| 6303-1089923PCF5 | 5/2 Secondary reference U.S. Government activity |
NSN 5950-00-369-1358 is a Transformer,current, manufactured by Ward Leonard Ct Llc, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-00-369-1358 has 4 manufacturer part numbers on file: 50065-3CPCF5 (Ward Leonard Ct Llc), 50064APC1T04 (Ward Leonard Ct Llc), 16535-67-1 (Ward Leonard Ct Llc), 50083-1ASH1PCF2 (Ward Leonard Ct Llc).
Key specifications for 50065-3CPCF5: Mounting Facility Quantity: 4 FIRST GROUP; Inclosure Type: OPEN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT; Body Width: 6.125 INCHES NOMINAL IN. 11 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.