PartsTable TECHNICAL DATA SHEET
NSN 5950-00-249-0884Government record, cited

Transformer, Radio Frequency5950-00-249-0884

NSN 5950-00-249-0884 · NIIN 002490884 · Part number 50C466
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 26916
Government record, cited
NSN 5950-00-249-0884 — this item is cataloged by the U.S. Government under National Stock Number 5950-00-249-0884. Manufacturer of record part number: 50C466.
Also searched as  5950-00-249-0884 · 5950002490884 · NIIN 002490884 · 00-249-0884 · FSC 5950 Coils and Transformers · CAGE 26916 · 50C466
Nearby stock numbers  ·
Features
  • Transformer,radio Frequency — FSC 5950
  • Mounting Facility Quantity: 2 SINGLE GROUP2 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSEDFULLY INCLOSED
  • Turn Quantity: 100 SINGLE COMPONENT SINGLE PRIMARY100 SINGLE COMPONENT SINGLE PRIMARY
  • Mounting Method: THREADED STUD(S) SINGLE GROUPTHREADED STUD(S) SINGLE GROUP
  • Inductance Rating: 57.00 MICROHENRIES NOMINAL AND 57.00 MICROHENRIES NOMINAL AND 150.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE PRIMARY150.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE PRIMARY
  • Adjustment Device Drive Type: SLOTTED SCREW SINGLE COMPONENTSLOTTED SCREW SINGLE COMPONENT
  • Body Width: 1.188 INCHES NOMINAL1.188 INCHES NOMINAL IN
Identification
  • NSN: 5950-00-249-0884
  • NIIN: 002490884
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 50C466
  • Manufacturer: Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple
General Description

The Transformer,radio Frequency, cataloged under National Stock Number 5950-00-249-0884, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple. Government technical data includes 19 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-249-0884
Primary Part Number50C466
Item NameTransformer,radio Frequency
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerNorthrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple
StatusACTIVE
Mounting Facility Quantity2 SINGLE GROUP2 SINGLE GROUP
Inclosure TypeFULLY INCLOSEDFULLY INCLOSED
Turn Quantity100 SINGLE COMPONENT SINGLE PRIMARY100 SINGLE COMPONENT SINGLE PRIMARY
Mounting MethodTHREADED STUD(S) SINGLE GROUPTHREADED STUD(S) SINGLE GROUP
Inductance Rating57.00 MICROHENRIES NOMINAL AND 57.00 MICROHENRIES NOMINAL AND 150.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE PRIMARY150.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Adjustment Device Drive TypeSLOTTED SCREW SINGLE COMPONENTSLOTTED SCREW SINGLE COMPONENT
Body Width1.188 INCHES NOMINAL1.188 INCHES NOMINAL IN
Body Height1.188 INCHES NOMINAL1.188 INCHES NOMINAL IN
Adjustment Method and Quantity1 ADJUSTABLE CORE SINGLE COMPONENT1 ADJUSTABLE CORE SINGLE COMPONENT
Winding Conductor Size0.00280 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE PRIMARY0.00280 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE PRIMARY IN
Coil Form TypeHOLLOW SINGLE COMPONENTHOLLOW SINGLE COMPONENT
Winding Function and Quantity1 PRIMARY SINGLE COMPONENT1 PRIMARY SINGLE COMPONENT
Distance Between Mounting Facility Centers0.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP0.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Nominal Thread Size0.138 INCHES SINGLE GROUP0.138 INCHES SINGLE GROUP IN
Body Length3.000 INCHES NOMINAL3.000 INCHES NOMINAL IN
Frequency Rating455.0 KILOHERTZ MAXIMUM SINGLE COMPONENT455.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
Thread Quantity Per Inch32 SINGLE GROUP32 SINGLE GROUP
Terminal Type and Quantity3 SOLDER STUD3 SOLDER STUD
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUPUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
50C466 PRIMARY Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple (USA)
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-00-249-0884?

NSN 5950-00-249-0884 is a Transformer,radio Frequency, manufactured by Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-00-249-0884?

NSN 5950-00-249-0884 has 1 manufacturer part number on file: 50C466 (Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple).

What are the specifications of 50C466?

Key specifications for 50C466: Mounting Facility Quantity: 2 SINGLE GROUP2 SINGLE GROUP; Inclosure Type: FULLY INCLOSEDFULLY INCLOSED; Turn Quantity: 100 SINGLE COMPONENT SINGLE PRIMARY100 SINGLE COMPONENT SINGLE PRIMARY; Mounting Method: THREADED STUD(S) SINGLE GROUPTHREADED STUD(S) SINGLE GROUP. 19 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-249-0884 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com