The Reactor-Transformer, cataloged under National Stock Number 5950-00-244-7511, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 18 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-244-7511 |
| Item Name | Reactor-Transformer |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | HERMETICALLY SEALED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 3.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| Mounting Method | THREADED STUD(S) SINGLE GROUP |
| Inductance Rating | 0.10 HENRY NOMINAL SINGLE COMPONENT SINGLE WINDING |
| Winding Function and Quantity | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| Nominal Thread Size | 0.164 INCHES SINGLE GROUP IN |
| Winding Operating Current | 0.8 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING |
| Rating Method | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
| DC Resistance Rating in Ohms | 0.020 SINGLE COMPONENT SINGLE WINDING |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 2.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 115.00 AC VOLTS NOMINAL AND 22.00 DC VOLTS NOMINAL SINGLE COMPONENT SINGLE WINDING |
| Terminal Type and Quantity | 12 SOLDERLESS LUG |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 7900088-00 | 3/2 Design control — primary reference U.S. Government activity |
| A16805 | 5/9 Secondary reference Te Connectivity Networks, Inc. Div Adc Telecommunications Sales, Inc. |
| S4108A | 5/2 Secondary reference U.S. Government activity |
NSN 5950-00-244-7511 is a Reactor-Transformer, classified under FSC 5950, Coils and Transformers. Status: active.
1 possible match (shared part number, not a government interchangeability claim): 3020-01-257-0277. Verify interchangeability with system specifications before substitution.
Key specifications for 5950-00-244-7511: Overall Height: 2.875 INCHES MAXIMUM IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 18 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.