The Reactor, cataloged under National Stock Number 5950-00-244-5179, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 16 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-244-5179 |
| Item Name | Reactor |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP4 SINGLE GROUP |
| Inclosure Type | HERMETICALLY SEALEDHERMETICALLY SEALED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Mounting Method | THREADED STUD(S) SINGLE GROUPTHREADED STUD(S) SINGLE GROUP |
| Inductance Rating | 12.00 HENRY MAXIMUM SINGLE COMPONENT SINGLE WINDING12.00 HENRY MAXIMUM SINGLE COMPONENT SINGLE WINDING |
| Body Width | 3.280 INCHES NOMINAL3.280 INCHES NOMINAL IN |
| Body Height | 4.290 INCHES NOMINAL4.290 INCHES NOMINAL IN |
| Body Length | 3.650 INCHES NOMINAL3.650 INCHES NOMINAL IN |
| Winding Operating Current | 150.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING150.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
| Rating Method | ELECTRICAL SINGLE COMPONENT SINGLE WINDINGELECTRICAL SINGLE COMPONENT SINGLE WINDING |
| DC Resistance Rating in Ohms | 150.000 SINGLE COMPONENT SINGLE WINDING150.000 SINGLE COMPONENT SINGLE WINDING |
| Reliability Indicator | NOT ESTABLISHEDNOT ESTABLISHED |
| Winding Quantity | 1 SINGLE COMPONENT1 SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Terminal Type and Quantity | 2 TAB, SOLDER LUG2 TAB, SOLDER LUG |
| Inductance Type | FIXEDFIXED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| SCC85142 | 3/2 Design control — primary reference U.S. Government activity |
| 8-4 | C/1 Advisory reference — outside the item-of-supply concept Smart Machines, Inc. Dba Barker and Williamson |
| 8-4 | 5/9 Secondary reference Barker & Williamson |
NSN 5950-00-244-5179 is a Reactor, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-00-244-5179: Mounting Facility Quantity: 4 SINGLE GROUP4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALEDHERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Mounting Method: THREADED STUD(S) SINGLE GROUPTHREADED STUD(S) SINGLE GROUP. 16 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.