Features
  • Reactor — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALEDHERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Mounting Method: THREADED STUD(S) SINGLE GROUPTHREADED STUD(S) SINGLE GROUP
  • Inductance Rating: 5.00 HENRY MAXIMUM SINGLE COMPONENT SINGLE WINDING5.00 HENRY MAXIMUM SINGLE COMPONENT SINGLE WINDING
  • Body Width: 3.280 INCHES NOMINAL3.280 INCHES NOMINAL IN
  • Body Height: 4.290 INCHES NOMINAL4.290 INCHES NOMINAL IN
Identification
  • NSN: 5950-00-243-5297
  • NIIN: 002435297
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Reactor, cataloged under National Stock Number 5950-00-243-5297, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-243-5297
Item NameReactor
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALEDHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Mounting MethodTHREADED STUD(S) SINGLE GROUPTHREADED STUD(S) SINGLE GROUP
Inductance Rating5.00 HENRY MAXIMUM SINGLE COMPONENT SINGLE WINDING5.00 HENRY MAXIMUM SINGLE COMPONENT SINGLE WINDING
Body Width3.280 INCHES NOMINAL3.280 INCHES NOMINAL IN
Body Height4.290 INCHES NOMINAL4.290 INCHES NOMINAL IN
Body Length3.650 INCHES NOMINAL3.650 INCHES NOMINAL IN
Winding Operating Current110.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING110.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
DC Resistance Rating in Ohms30.000 SINGLE COMPONENT SINGLE WINDING30.000 SINGLE COMPONENT SINGLE WINDING
Reliability IndicatorNOT ESTABLISHEDNOT ESTABLISHED
Winding Quantity1 SINGLE COMPONENT1 SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Terminal Type and Quantity2 STANDOFF, SOLDER LUG2 STANDOFF, SOLDER LUG
Inductance TypeFIXEDFIXED
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
SCC85143 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-00-243-5297?

NSN 5950-00-243-5297 is a Reactor, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-00-243-5297?

Key specifications for 5950-00-243-5297: Mounting Facility Quantity: 4 SINGLE GROUP4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALEDHERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Mounting Method: THREADED STUD(S) SINGLE GROUPTHREADED STUD(S) SINGLE GROUP. 15 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-243-5297 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com