PartsTable TECHNICAL DATA SHEET
NSN 5950-00-230-8541Government record, cited

Transformer, Power5950-00-230-8541

NSN 5950-00-230-8541 · NIIN 002308541
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-230-8541 · 5950002308541 · NIIN 002308541 · 00-230-8541 · FSC 5950 Coils and Transformers · 366P5 · 504-0040
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 ALL GROUPINGS
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.245 INCHES MINIMUM AND 1.255 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS IN
  • Input-Output Phase Relationship: THREE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: UNTHREADED HOLE(S) ALL GROUPINGS
  • Body Width: 1.875 INCHES MAXIMUM IN
  • Body Height: 1.000 INCHES MAXIMUM IN
Identification
  • NSN: 5950-00-230-8541
  • NIIN: 002308541
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-230-8541, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 20 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-230-8541
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 ALL GROUPINGS
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length1.245 INCHES MINIMUM AND 1.255 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS IN
Input-Output Phase RelationshipTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodUNTHREADED HOLE(S) ALL GROUPINGS
Body Width1.875 INCHES MAXIMUM IN
Body Height1.000 INCHES MAXIMUM IN
Mounting Hole Diameter0.090 INCHES NOMINAL SECOND GROUP IN
Mounting Hole Diameter0.187 INCHES NOMINAL FIRST GROUP IN
Winding Function and Quantity1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
Maximum Operating Temp155.0 CELSIUS DEGC
Body Length2.000 INCHES MAXIMUM IN
Winding Operating Current400.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT ALL SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.464 INCHES MINIMUM AND 1.474 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS IN
Winding Operating Voltage208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage37.20 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
Terminal Type and Quantity10 TAB, SOLDER LUG
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5962-01-231-08605226460-1 POSSIBLE MATCH
MICROCIRCUIT,LINEAR
Possible match (shared part number)Raytheon Company Dba Raytheon Co
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
366P5 5/9 Secondary reference
A.e.york, Llc
504-0040 3/9 Design control — primary reference
Lockheed Martin Corporation Div Lockheed Martin Information Systems & Global Solutions
Related Parts
5962-01-231-0860POSSIBLE MATCH
MICROCIRCUIT,LINEAR
5226460-1

Frequently Asked Questions

What is NSN 5950-00-230-8541?

NSN 5950-00-230-8541 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-00-230-8541?

1 possible match (shared part number, not a government interchangeability claim): 5962-01-231-0860. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-00-230-8541?

Key specifications for 5950-00-230-8541: Mounting Facility Quantity: 4 ALL GROUPINGS; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.245 INCHES MINIMUM AND 1.255 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS IN; Input-Output Phase Relationship: THREE PHASE TO SINGLE PHASE SINGLE COMPONENT. 20 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-230-8541 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com