PartsTable TECHNICAL DATA SHEET
NSN 5950-00-219-5595Government record, cited

Transformer, Power5950-00-219-5595

NSN 5950-00-219-5595 · NIIN 002195595 · Part number L01273
Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings) · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 16236
Government record, cited
NSN 5950-00-219-5595 — this item is cataloged by the U.S. Government under National Stock Number 5950-00-219-5595. Manufacturer of record part number: L01273.
Also searched as  5950-00-219-5595 · 5950002195595 · NIIN 002195595 · 00-219-5595 · FSC 5950 Coils and Transformers · CAGE 16236 · L01273 · 5950PL0944915 · 27V91
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 3.063 INCHES NOMINAL IN
  • Body Height: 4.875 INCHES NOMINAL IN
Identification
  • NSN: 5950-00-219-5595
  • NIIN: 002195595
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: L01273
  • Manufacturer: Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings)
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-219-5595, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings). Government technical data includes 22 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-219-5595
Primary Part NumberL01273
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerDla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings)
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width3.063 INCHES NOMINAL IN
Body Height4.875 INCHES NOMINAL IN
Criticality Code JustificationFEAT
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Winding Shielding MethodCORE GROUNDED SINGLE COMPONENT
Nominal Thread Size0.164 INCHES SINGLE GROUP IN
Body Length3.563 INCHES NOMINAL IN
Winding Operating Current6.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Current4.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Thread Quantity Per Inch32 SINGLE GROUP
Winding Operating Voltage70.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Winding Operating Voltage105.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity7 SOLDER STUD
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeY
Cross-Reference Index
Part NumberManufacturer
L01273 PRIMARY Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings) (USA)
Reference documents
ReferenceMeaning
5950PL0944915 6/9 Informative reference only
Jednolity Indeks Materialowy - Uniform Material Index
27V91 3/1 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-00-219-5595?

NSN 5950-00-219-5595 is a Transformer,power, manufactured by Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings), classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-00-219-5595?

NSN 5950-00-219-5595 has 1 manufacturer part number on file: L01273 (Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings)).

What are the specifications of L01273?

Key specifications for L01273: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 22 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-219-5595 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.