PartsTable TECHNICAL DATA SHEET
NSN 5950-00-197-4605Government record, cited

Transformer, Power5950-00-197-4605

NSN 5950-00-197-4605 · NIIN 001974605
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-197-4605 · 5950001974605 · NIIN 001974605 · 00-197-4605 · FSC 5950 Coils and Transformers · KS9771 · B0103660
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 4.844 INCHES NOMINAL IN
  • Body Height: 5.312 INCHES NOMINAL IN
Identification
  • NSN: 5950-00-197-4605
  • NIIN: 001974605
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-197-4605, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 26 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-197-4605
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length3.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width4.844 INCHES NOMINAL IN
Body Height5.312 INCHES NOMINAL IN
Winding Function and Quantity1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
Nominal Thread Size0.250 INCHES SINGLE GROUP IN
Body Length5.438 INCHES NOMINAL IN
Winding Operating Current2.0 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current18.0 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current18.0 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current246.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating57.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width4.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Thread Quantity Per Inch20 SINGLE GROUP
Winding Operating Voltage5.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage2.80 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage2.80 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage636.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Terminal Type and Quantity11 STANDOFF INSULATOR
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
KS9771 3/9 Design control — primary reference
Lucent Technologies Inc Advanced Technology Systems
B0103660 5/9 Secondary reference
Lucent Technologies Inc Advanced Technology Systems
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-00-197-4605?

NSN 5950-00-197-4605 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-00-197-4605?

Key specifications for 5950-00-197-4605: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 26 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-197-4605 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com