The Transformer,power, cataloged under National Stock Number 5950-00-138-0511, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is L3harris Technologies, Inc Div Space & Airborne Systems. Government technical data includes 19 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-138-0511 |
| Primary Part Number | 160106-1 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | L3harris Technologies, Inc Div Space & Airborne Systems |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | HERMETICALLY SEALED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 14.950 INCHES MINIMUM AND 15.050 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Power Rating | 10.5 KILOVOLT-AMPERES SINGLE COMPONENT ALL SECONDARY |
| Input-Output Phase Relationship | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| Mounting Method | UNTHREADED HOLE(S) SINGLE GROUP |
| Mounting Hole Diameter | 0.450 INCHES MINIMUM AND 0.480 INCHES MAXIMUM SINGLE GROUP IN |
| Winding Function and Quantity | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| Maximum Operating Temp | 130.0 CELSIUS DEGC |
| Body Length | 16.000 INCHES MAXIMUM IN |
| Winding Operating Current | 2.1 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 8.950 INCHES MINIMUM AND 9.050 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Test Data Document | 24930-160106 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| Winding Operating Voltage | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 5.00 AC KILOVOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
| Terminal Type and Quantity | 24 THREADED STUD |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 160106-1 PRIMARY | L3harris Technologies, Inc Div Space & Airborne Systems (USA) |
NSN 5950-00-138-0511 is a Transformer,power, manufactured by L3harris Technologies, Inc Div Space & Airborne Systems, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-00-138-0511 has 1 manufacturer part number on file: 160106-1 (L3harris Technologies, Inc Div Space & Airborne Systems).
Key specifications for 160106-1: Overall Height: 10.690 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 14.950 INCHES MINIMUM AND 15.050 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 19 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.