Features
  • Reactor-Transformer — FSC 5950
  • Mounting Facility Quantity: 8 ALL GROUPINGS
  • Inclosure Type: HERMETICALLY SEALED WITH OIL
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 6.690 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SECOND COMPONENT
  • Input-Output Phase Relationship: THREE PHASE TO THREE PHASE FIRST COMPONENT
  • Mounting Method: THREADED HOLE(S) ALL GROUPINGS
  • Inductance Rating: 0.80 MILLIHENRIES MINIMUM SECOND COMPONENT SINGLE WINDING
Identification
  • NSN: 5950-00-062-1499
  • NIIN: 000621499
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Reactor-Transformer, cataloged under National Stock Number 5950-00-062-1499, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-062-1499
Item NameReactor-Transformer
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity8 ALL GROUPINGS
Inclosure TypeHERMETICALLY SEALED WITH OIL
Center to Center Distance Between Mounting Facilities Parallel to Length6.690 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SECOND COMPONENT
Input-Output Phase RelationshipTHREE PHASE TO THREE PHASE FIRST COMPONENT
Mounting MethodTHREADED HOLE(S) ALL GROUPINGS
Inductance Rating0.80 MILLIHENRIES MINIMUM SECOND COMPONENT SINGLE WINDING
Body Width6.650 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY FIRST COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
Nominal Thread Size0.250 INCHES ALL GROUPINGS IN
Maximum Operating Temp105.0 CELSIUS DEGC
Body Length7.920 INCHES MAXIMUM IN
Winding Operating Current60.5 AMPERES AC MAXIMUM FIRST COMPONENT SINGLE SECONDARY
Winding Operating Current80.0 AMPERES DC MAXIMUM SECOND COMPONENT SINGLE WINDING
Rating MethodELECTRICAL FIRST COMPONENT SINGLE PRIMARY
Rating MethodELECTRICAL FIRST COMPONENT SINGLE SECONDARY
Rating MethodELECTRICAL SECOND COMPONENT SINGLE WINDING
DC Resistance Rating in Ohms0.006 SECOND COMPONENT SINGLE WINDING
Reliability IndicatorNOT ESTABLISHED
Frequency Rating2.4 KILOHERTZ NOMINAL SECOND COMPONENT
Frequency Rating360.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM FIRST COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width5.420 INCHES MINIMUM AND 5.460 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP IN
Thread Quantity Per Inch20 ALL GROUPINGS
Winding Operating Voltage0.70 AC VOLTS NOMINAL SECOND COMPONENT SINGLE WINDING
Winding Operating Voltage10.00 AC VOLTS NOMINAL FIRST COMPONENT SINGLE SECONDARY
Winding Operating Voltage120.00 AC VOLTS NOMINAL OR 208.00 AC VOLTS NOMINAL FIRST COMPONENT SINGLE PRIMARY
Terminal Type and Quantity11 STANDOFF, THREADED STUD
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) ALL GROUPINGS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
A17232 5/9 Secondary reference
Te Connectivity Networks, Inc. Div Adc Telecommunications Sales, Inc.
7901833-00 3/2 Design control — primary reference
U.S. Government activity
S-5163 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-00-062-1499?

NSN 5950-00-062-1499 is a Reactor-Transformer, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-00-062-1499?

Key specifications for 5950-00-062-1499: Overall Height: 7.310 INCHES MAXIMUM IN; Mounting Facility Quantity: 8 ALL GROUPINGS; Inclosure Type: HERMETICALLY SEALED WITH OIL; Center to Center Distance Between Mounting Facilities Parallel to Length: 6.690 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP IN. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-062-1499 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com