PartsTable TECHNICAL DATA SHEET
NSN 5950-00-006-1291Government record, cited

Reactor5950-00-006-1291

NSN 5950-00-006-1291 · NIIN 000061291
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-00-006-1291 · 5950000061291 · NIIN 000061291 · 00-006-1291 · FSC 5950 Coils and Transformers · 25302-6 · 539450-6
Nearby stock numbers  ·
Features
  • Reactor — FSC 5950
  • Inclosure Type: FULLY INCLOSED
  • Body Outside Diameter: 0.660 INCHES MAXIMUM IN
  • Mounting Method: TERMINAL SINGLE GROUP
  • Inductance Rating: 2.40 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
  • Body Length: 0.390 INCHES MAXIMUM IN
  • Winding Operating Current: 63.2 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
  • Rating Method: ELECTRICAL SINGLE COMPONENT SINGLE WINDING
Identification
  • NSN: 5950-00-006-1291
  • NIIN: 000061291
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Reactor, cataloged under National Stock Number 5950-00-006-1291, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 13 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-006-1291
Item NameReactor
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Inclosure TypeFULLY INCLOSED
Body Outside Diameter0.660 INCHES MAXIMUM IN
Mounting MethodTERMINAL SINGLE GROUP
Inductance Rating2.40 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
Body Length0.390 INCHES MAXIMUM IN
Winding Operating Current63.2 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
Rating MethodELECTRICAL SINGLE COMPONENT SINGLE WINDING
DC Resistance Rating in Ohms2.900 SINGLE COMPONENT SINGLE WINDING
Reliability IndicatorNOT ESTABLISHED
Winding Quantity1 SINGLE COMPONENT
Frequency Rating5.0 KILOHERTZ NOMINAL SINGLE COMPONENT
Terminal Type and Quantity2 WIRE LEAD
Inductance TypeFIXED
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 2
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5360-01-178-150325-3026 POSSIBLE MATCH
SPRING
Possible match (shared part number)Gardner Denver Water Jetting Systems, Inc. Div Engineered Package Group
4730-01-538-0153 POSSIBLE MATCH
ADAPTER,STRAIGHT,HOSE TO BOSS
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
25302-6 5/2 Secondary reference
U.S. Government activity
539450-6 3/2 Design control — primary reference
U.S. Government activity
Related Parts
5360-01-178-1503POSSIBLE MATCH
SPRING
25-3026
4730-01-538-0153POSSIBLE MATCH
ADAPTER,STRAIGHT,HOSE TO BOSS

Frequently Asked Questions

What is NSN 5950-00-006-1291?

NSN 5950-00-006-1291 is a Reactor, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-00-006-1291?

2 possible matches (shared part number, not a government interchangeability claim): 5360-01-178-1503, 4730-01-538-0153. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-00-006-1291?

Key specifications for 5950-00-006-1291: Inclosure Type: FULLY INCLOSED; Body Outside Diameter: 0.660 INCHES MAXIMUM IN; Mounting Method: TERMINAL SINGLE GROUP; Inductance Rating: 2.40 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING. 13 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-006-1291 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com