The Transformer,power, cataloged under National Stock Number 5950-00-004-6167, is classified within Federal Supply Class 5950 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Raytheon Company Dba Raytheon. Government technical data includes 26 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 4 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-00-004-6167 |
| Primary Part Number | 984659-1 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — No Item Name Available |
| Manufacturer | Raytheon Company Dba Raytheon |
| Status | ACTIVE |
| Input-Output Phase Relationship | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| Reliability Indicator | NOT ESTABLISHED |
| Winding Operating Current | 47.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| Inclosure Type | FULLY INCLOSED |
| Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Winding Operating Current | 2.36 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Body Length | 4.500 INCHES MAXIMUM IN |
| Winding Shielding Method | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| Body Width | 2.600 INCHES MAXIMUM IN |
| Terminal Type and Quantity | 19 TAB, SOLDER LUG |
| Mounting Method | THREADED HOLE(S) SINGLE GROUP |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Current | 11.3 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Body Height | 3.780 INCHES NOMINAL IN |
| Nominal Thread Size | 0.164 INCHES SINGLE GROUP IN |
| Winding Operating Voltage | 7.50 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Voltage | 5.30 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Voltage | 46.50 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Current | 11.3 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Transformer Winding Connection Type | DELTA-DELTA |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 2.270 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 199.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 39.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| Winding Function and Quantity | 1 PRIMARY AND 5 SECONDARY SINGLE COMPONENT |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 311-13666-01 | Oeco, Llc Dba Pacific Scientific Oeco Div Fire Safety and Power Systems (USA) |
| 18162 | Robert M. Hadley Company, Inc. (USA) |
| 860511 | Raytheon Company Dba Raytheon (USA) |
| 984659-1 PRIMARY | Raytheon Company Dba Raytheon (USA) |
NSN 5950-00-004-6167 is a Transformer,power, manufactured by Raytheon Company Dba Raytheon, classified under FSC 5950 (No Item Name Available). Status: active.
NSN 5950-00-004-6167 has 4 cross-referenced part numbers: 311-13666-01 (Oeco, Llc Dba Pacific Scientific Oeco Div Fire Safety and Power Systems), 18162 (Robert M. Hadley Company, Inc.), 860511 (Raytheon Company Dba Raytheon), 984659-1 (Raytheon Company Dba Raytheon).
There are 4 known substitutes for 5950-00-004-6167: 3110-00-156-4719, 2995-00-909-9935, 5962-01-123-5448 and 1 more. Verify interchangeability with system specifications before substitution.
Key specifications for 984659-1: Input-Output Phase Relationship: THREE PHASE TO THREE PHASE SINGLE COMPONENT; Reliability Indicator: NOT ESTABLISHED; Winding Operating Current: 47.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY; Inclosure Type: FULLY INCLOSED. 27 total characteristics are documented in the Federal Logistics Information System.