PartsTable TECHNICAL DATA SHEET
NSN 5950-00-001-6545Government record, cited

Transformer, Power5950-00-001-6545

NSN 5950-00-001-6545 · NIIN 000016545 · Part number 3024797
Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 10001
Government record, cited
NSN 5950-00-001-6545 — this item is cataloged by the U.S. Government under National Stock Number 5950-00-001-6545. Manufacturer of record part number: 3024797.
Also searched as  5950-00-001-6545 · 5950000016545 · NIIN 000016545 · 00-001-6545 · FSC 5950 Coils and Transformers · CAGE 10001 · 3024797 · 149932
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Transformer Winding Connection Type: DELTA-DELTA
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: THREE PHASE TO THREE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 3.375 INCHES NOMINAL IN
Identification
  • NSN: 5950-00-001-6545
  • NIIN: 000016545
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 3024797
  • Manufacturer: Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier
General Description

The Transformer,power, cataloged under National Stock Number 5950-00-001-6545, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier. Government technical data includes 26 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-00-001-6545
Primary Part Number3024797
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerNavair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier
StatusACTIVE
Transformer Winding Connection TypeDELTA-DELTA
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipTHREE PHASE TO THREE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width3.375 INCHES NOMINAL IN
Body Height5.250 INCHES NOMINAL IN
Winding Function and Quantity1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
Nominal Thread Size0.190 INCHES SINGLE GROUP IN
Body Length3.938 INCHES NOMINAL IN
Winding Operating Current3.0 AMPERES DC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current3.0 AMPERES DC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current15.0 AMPERES DC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current250.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating50.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage16.70 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage18.10 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage38.10 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Voltage8.50 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Terminal Type and Quantity15 TAB, SOLDER LUG
Thread Series DesignatorUNF SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5975-00-222-3497149932 POSSIBLE MATCH
SLEEVE,CABLE
Possible match (shared part number)Mag Aerospace Industries, Llc Div Safran Cabins
Cross-Reference Index
Part NumberManufacturer
3024797 PRIMARY Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier (USA)
149932 Northrop Grumman Systems Corporation (USA)
Reference documents
ReferenceMeaning
3024797 5/9 Secondary reference
Signal Transformer Co Inc
Related Parts
5975-00-222-3497POSSIBLE MATCH
SLEEVE,CABLE
149932

Frequently Asked Questions

What is NSN 5950-00-001-6545?

NSN 5950-00-001-6545 is a Transformer,power, manufactured by Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-00-001-6545?

NSN 5950-00-001-6545 has 2 manufacturer part numbers on file: 3024797 (Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier), 149932 (Northrop Grumman Systems Corporation).

What NSN replaces 5950-00-001-6545?

1 possible match (shared part number, not a government interchangeability claim): 5975-00-222-3497. Verify interchangeability with system specifications before substitution.

What are the specifications of 3024797?

Key specifications for 3024797: Transformer Winding Connection Type: DELTA-DELTA; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 26 specifications are documented in the U.S. Government catalog.

Is NSN 5950-00-001-6545 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com